    Automatic gaseous fire control panel is a small dimension fashion appearance system, which is a product special designed to work with fire suppression systems, to suppress fire automatically and completely.

    • Description
    • Features and Applications
    • Extra Information
    • Other Precautions

    This automatic fire alarm control panel is comply with EU standard EN54-2 and EN54-4, and meet with fire fighting standard EN12094-1.

    It normally work with gas fire suppression systems, aerosol fire extinguisher device and dry chemical powder fire extinguisher, so we often call it “automatic gas fire extinguisher panel”.

    It is fashion in design, small dimension and Do-It-Yourself Installation.

    Hereby below are the main parameters of it:

    • Model: AW-GEC2169.
    • Dimension: 280*112.50*350 mm.
    • AC input: 220 VAC at 50HZ.
    • DC output from power board: 24VDC (19V-28V), 5VDC (4.9V-5.1V).
    • Volt. for MCU: 5 volt for power board MCU and 3.3 volt for others.
    • Maximum current: 1.4A except batteries charge.
    • Current at 24 VDC: <450mA standby current.
    • Battery and battery current: 2*12V/ 2.3Ah sealed lead acid gel, self-regulated; 1.85A maximum, current limited.
    • Auxiliary output: 24 VDC, 200 mA maximum, current limited.
    • Fire suppression system discharging delay time: 0 to 60 seconds adjustable.
    • Battery replace resistance: 1.6Ω±10%. (if needed).
    • Battery low-voltage protection: 21 to 24 V.
    • Alarm terminal output current: Maximum at 200 mA.
    • Relay contact rating: 1A at 30 VDC.
    • Detectors wiring allowed for each zone: 16 devices (except mCPS).
    • Zone alarm current: 6mA minimum, 27mA maximum.
    • Communication protocol: 2 wires RS485 bus system.
    • Relative humidity: ≤95%, non-condensing.
    • Wires between interface board (panel) and detector: 2-core shielded cable for 12 to18 AWG
    • Product weight: 9900 grams with batteries.

    This product can match FM200 fire suppression system perfectly.

    It has the following particular features:

    • It is durable, because outside have a metal cabinet to protect it, and also have a visiable glass window.
    • The delay time is resettable, the delay time is range from 0 to 60 seconds adjustable.
    • Power switch freely, between AC and Stand-by battery.
    • Anti-wrong operation: Press abort to stop the fire extinguishing system to be released under wrong operation.
    • GSM module optional installation.
    • It is multi-functional, reset at 24VDC port, it can connect 4 wire devices.
    • Early-alarm: Early alarm is the first stage fire alarm.
    • Comply with international standard of EN54-2, EN54-4 and EN12094-1.

     

     

     

    This aerosol fire control panel is with CE certificate and meet with EU safety standard, which is special design for following style of fire suppression systems.

    • Wall mounted aerosol.
    • Minisol aerosol.
    • Floor standing aerosol.
    • Carbon dioxide.
    • IG541 inert gas.
    • HFC-227ea FM200 Heptafluoropropane.
    • Novec 1230 PERFLUORO.
    • Super-fine ABC dry chemical powder.
    • Foam system.

    PACKING DETAILS

    • Inner is packed with high quality of PEE bag.
    • Each device packed with standard export carton box.
    • It normally accompany with other fire suppression systems, and when arrive at China seaport, we will pack it into a big fumigation wooden case.

    TRANSPORTATION INFORMATION

    • Keep it in a dry and ventilated place.
    • Handle with care during its transportation.

    ATTENTION!

    • Do not disassemble this device without permission.

    Enquiry Form ( we will get back you as soon as possible )

    Name:
    *
    Email:
    *
    Message:

    Verification:
    5 + 6 = ?

    Maybe you like also

  • WHY CHOOSE US

    We are a ISO 9001, ISO14001, ISO18001 certificated manufacturer specialize in fire suppression system for a decade of years, we use top quality of material to produce the products and all of them have pass strictly QC inspection before leaving factory, most of our products have got certificates and approvlas of CE, RHOS, IP67, GL, Chinese Language of Test Report from China Institute.

  • CONTACT US

    Jiangxi Aware Fire Technology Co.,Ltd

    Address: Number 112, Yushui District, Xinyu City, Jiangxi Province, Republic of China.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail:  sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com