Computer Room Server Rack Aerosol Fire Prevention System

Floor standing aerosol chemical based fire prevention system is ideal solution for any enclosure space with area of 30 to 2000 cubic meters, for example, if a computer room or sever rack room is in a size of 10*8*4 meters, then several sets of this device would be able to install in the corner of the room as a fire suppression solution.

In case the space is below 30 cubic meters, then another series of MINISOL aerosol will be the best solution; in case space is below 1 cubic meter, then we suggest the Lithium-ion Battery style Aerosol.

  • Description
  • Features and Application
  • Extra Information
  • Other Precautions

BASIC INFORMATION

There is an aerosol fire prevention system which looks like an air conditioner, it can stand on the floor and do not require any installation.

It is even halon alternative and HFC-227ea alternative in some special fields, such as: small computer room, server racks, telecommunication room and other.

Floor standing aerosol is a advanced environmentally friendly product with advanced technology, it is the latest Third Generation-Type S Aerosol.

Aerosol technology comes from the rocket technology of Russian Army, and then some Russia high-tech company produce out the first generation aerosol system, we Jiangxi Aware Fire Technology Co.,Ltd are the first import the aerosol technology from Russia, and improved their technology to form our China Unique aerosol-Strontium Nitrate Based, which is much more environment friendly and human friendly than that of Potassium Nitrate Based Aerosol.

Floor standing type is electric start-up only, but can be able to have signal feedback, below we will explain its features and data.

SPECIFICATIONS AND PARAMETERS

In the following we list our the main technical parameters:

  • Product Type: Floor Standing or Ground Type.
  • Pattern: AW-QRR5LW/S, AW-QRR7.5LW/S, AW-QRR8LW/S, AW-QRR10LW/S.
  • Activation Style: Electric Start.
  • Cover Volume: From 35 m3 to 71 m3.
  • Discharging time: less than 120 seconds.
  • Size: See the INSTALLATION MANUAL.
  • Ambient Temperature: from -20℃ to +55℃.
  • Relative Humidity: ≤98%.
  • Actual Extinguishing Efficiency: 130-150 gram per cubic meters.
  • Cylinder Surface Temperature: less than 100℃.
  • Colour of the Cylinder: silver white and/or red.
  • Spout Temperature: less than 180℃ (5mm distance from spout.)
  • Feedback Signal Style: Normal Open.
  • Rated Start Current: 1 to 1.2 A.
  • Start Voltage: Direct Current: 3 to 24 volt; Alternating Current: 3 to 240 volt.
  • Life Span: 7 to 10 years.
  • Fire Suppression Type: A, B, C, E.
  • Installation Mode: Bracket with Screws; and Magnetic with 3M glue.
  • Supporting Equipment: Fire Alarm Systems.

It mainly apply in those enclosed space where the volume is range from 30 to 2000 cubic meters, for example: computer rooms, power generator rooms and other space.

FEATURES

An old technician in our workshop design out this style of aerosol device, which is similar like a external machine of air conditioner, His design was inspired by air conditioning, we all admire him.

Get back to the point, the features as follow:

  • It should be installed in enclosure space, not in open area.
  • It should use in those space range from 30 to 2000 cubic meters, and over 2000m3 you would better use a FM200 fire protection system.
  • It is clean product, do not worry about that it will do any damage to your machinery and equipment.
  • It leaves no residue after spraying, do not require you to sweep the room.
  • It is with a special cooling technology, so when it releasing the aerosol outlet temperature is not very hot.
  • It is a non-piping system, and do not worry about the problem of leakage.
  • Life span over 7 to 10 years, and during its service time, people do not need to do any maintenance on it.
  • Pass the fire test and inspection test from China official research institute, and get CE certificate for approval.
  • Do not require you to install it with any tools, just place it on the floor in the room.

APPLICATIONS

  • High-rise Buildings.
  • Power Distribution Room.
  • Library Room.
  • Archives Room.
  • Reference Room.
  • Storage Room.
  • Telecommunication Room.
  • Computer Rooms.
  • Communication Stations.
  • Railway Stations.
  • Distribution Ark.
  • Data Processing.
  • Remote Control.
  • Train Locomotive.
  • High Mobile Equipment Machine Room.
  • Signal Station Room.
  • Data Base Room.

RESTRICTED APPLICATION

This device not be able to apply in the following fields:

  • Chemical Substance which can be oxidized rapidly without air.
  • Active Metal.
  • Spontaneous Combustion Substance.
  • Metal Hydroxide.
  • Strong Oxidant.

ATTENTION FOR PRODUCT INSTALLATION

  • The installation job should be done by a professional person or skilled technician.
  • The device better installed near the wall.
  • The device should not be installed near wind, vent, door, window and other opening outlet.
  • Do not install it in a place where easy to get rain and water.
  • Do not install it near source of fire flame.
  • Do not install in evacuation exit.
  • Do not install it in a place where easy to get shocked, impacted and corrosion.
  • Mechanical ventilation equipment should be set at a underground pipe gallery or place without windows.
  • The device's activation wire better use twisted pair wire, or use dual-core metal shielded wire and the wire size better is 1.5 mm2.

ATTENTION FOR USE

Please read our instruction manual carefully before installation.

  • The job of installation and system commissioning must be done by a skilled personnel.
  • After installation, do not move the device easily.
  • In case of fire, personnel at site should leave immediately, and before leave please close the doors and windows as possible as you can.
  • The life span of this device is 7 years normally, after the service life time, please consider to replace it with a new one.
  • After releasing, don't touch the cylinder, because it is too hot, after cool down please wear gloves to move it.
  • In case of any accident, please do not dismantle the device without permission from the manufacturer or authorized agent.
  • The standby power of fire alarm system is forbidden to charge continuously for 24 hours, and the standby power should be replaced every 4 years.
  • The inspector should check the fire alarm system yearly and keep record, but do not need to check this device yearly.
  • Before put in use, the installer should make sure that the power is off, in case of any device activated by mistake.

TRANSPORTATION AND STORAGE

  • Handle with care during its transportation.
  • Store the device at a ventilated and dry warehouse.

AFTER SALES SERVICE

  • Warranty Time: 1 to 2 years based on manufacturing date.
  • Any technician question and doubt please feel free to inquiry from us.
  • After sale we can teach you how do install and how to do system debugging.

Enquiry Form ( we will get back you as soon as possible )

Name:
*
Email:
*
Message:

Verification:
5 + 9 = ?

Maybe you like also

  • WHY CHOOSE US

    We are a ISO 9001, ISO14001, ISO18001 certificated manufacturer specialize in fire suppression system for a decade of years, we use top quality of material to produce the products and all of them have pass strictly QC inspection before leaving factory, most of our products have got certificates and approvlas of CE, RHOS, IP67, GL, Chinese Language of Test Report from China Institute.

  • CONTACT US

    Jiangxi Aware Fire Technology Co.,Ltd

    Address: Number 112, Yushui District, Xinyu City, Jiangxi Province, Republic of China.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail:  sales@chinafiresuppresion.com