Cylinder Style FM200 Fire Detection Tube System

FM200 fire detection tube system with storage cylinder is a easy-to-install fire protection system for special hazards, such as: electrical control box and control panels, machinery.

Further inquiry please CONTACT US.

  • Description
  • Features
  • Applications
  • Other Infomation and Precautiions

FM200 fire detection tube system is a fire-fighting device for detecting fire and extinguishing fire, It has a red color tube small tube which is used for detect fire and suppress fire automatically, this device is made up of storage cylinders, detection tube, signal feedback device, it use HFC-227ea or CO2 as extinguishing agent, can be used for some special places, like some narrow spaces where not be able to install piping systems and not be able to install fire alarms.

It is a fire extinguishing system which is low in cost, simple in structure and reliable in performance.

It has two mode, one is direct mode, which use the red tube as fire detection and fire suppression medium together; another is indirect type, which use the red tube as fire detection medium, but use a 8mm copper pipe as fire suppression medium.

WORKING PRINCIPLE

Direct type: this kind of device connect with storage cylinder by way of ball valve and container head valve, and installed in the protection zone, the end terminal of the fire detection tube has a pressure gauge, which is used to show the pressure in the fire detection tube; When a fire occurs, the fire detection tube is heated, Fractured at the melting point of the fire detection tube, extinguishing agent is sprayed from the cracked hole to the source of the fire to suppress fire.

Indirect type: It detects fire by the fire detection tube, and control the opening and closing of the bottle head valve, and then suppress fire by the copper pipe and its nozzle to release HFC-227ea agent; the fire detection tube is connect with ball valve and container head valve, the releasing tube is connect with the outlet of the container head valve, when fire occurs, the fire detection tube will be heated, and the container vale is open to start the device, the fire extinguishing agent is spraying out from the copper pipe, to put out fire.

BASIC PARAMETERS AND DATA SHEET

  • Model: WZ-Q/T-3Q, WZ-Q/T-6Q, WZ-Q/T-12JQ(indirect).
  • Nominal Working Pressure: 2.5 Mpa.
  • Maximum Working Pressure: 4.2 Mpa.
  • Fill Pressure: 1.5 Mpa.
  • Fill Agent: HFC-227ea (or Carbon Dioxide system).
  • Ambient Temperature: 0 to 50℃.
  • Length of the fire detection tube: 20 to 25 meters.
  • Fire detection tube activation temperature: 160±10℃.
  • Tube outer diameter: 6mm, inner diameter: 4mm, wall thickness: 1 mm, tube density:1.05g/m³.
  • Copper pipe length: 12 meters (indirect type).
  • Effective Protection Volume: 4.6m³, 8.5m³, 17m³.

Furthermore, as per requirement, the fire detection tube also can be filled with extinguishing agent of Carbon dioxide.

  • Model: WZ-Q/T-3E, WZ-Q/T-6E, WZ-Q/T-24JE(indirect type), WZ-Q/T-42JE(indirect type).
  • Working storage pressure: 5.17 Mpa.
  • Cover area: 4.6m³, 8.5m³, 34m³, 60m³.

Fire detection tube system is also installed as per the design in format of .dwg or .pdf, just like piping FM200 systems and aerosol systems, it is a complete system with pressure switch, fire alarms etc.

Fire detection tube system is mainly be installed in electrical cabinet and control panels.

Its features and advantages as following:

  • The fire extinguishing agent is sprayed directly at the ignition point, suppress fire at its initial stage.
  • No external power supply required.
  • Fast detection and reaction times, so minimize damage caused by fire spread.
  • Not have accidental spray and delayed spray due to harsh environment.
  • Cost effective and simple structure.
  • Compact dimension, Easy to install and space saving.
  • Have three functions: fire detection, fire suppression and fire alarm.

It is widely apply in the following fields:

  • Petrochemical plant.
  • Pharmaceutical factory.
  • Communication equipment.
  • Power plant.
  • The kitchen.
  • Steel plaint.
  • Military equipment.
  • Banking equipment.
  • Subway facility.
  • Flammable goods warehouse.
  • Oil depot.
  • Computer room.
  • Electrical control box.
  • Distribution board.
  • Large workshops.
  • Business place.
  • Residential communities.
  • Railway station.
  • Residential communities.
  • Underground tunnels.
  • Storage room.
  • Computer room.
  • Entertainment plaza.

STORAGE

  • Store it in a dry and ventilated place.
  • Do move the device as per the instruction manual strictly.
  • Handle with care!

TRANSPORTATION AND

  • Transported by a special dangerous goods vehicle.
  • Keep far away from the sun and heat sources and rain.

Enquiry Form ( we will get back you as soon as possible )

Name:
*
Email:
*
Message:

Verification:
2 + 8 = ?

Maybe you like also

  • WHY CHOOSE US

    We are a ISO 9001, ISO14001, ISO18001 certificated manufacturer specialize in fire suppression system for a decade of years, we use top quality of material to produce the products and all of them have pass strictly QC inspection before leaving factory, most of our products have got certificates and approvlas of CE, RHOS, IP67, GL, Chinese Language of Test Report from China Institute.

  • CONTACT US

    Jiangxi Aware Fire Technology Co.,Ltd

    Address: Number 112, Yushui District, Xinyu City, Jiangxi Province, Republic of China.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail:  sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com