Κίνα Top Δέκα επιχειρήσεις στη βιομηχανία πυροπροστασίας και ασφάλειας
EnglishবাংলাБългарскиΕλληνικάItalianoLatīnaLatviešu valodaLietuvių kalbaPortuguêsRomânăSlovenčinaEspañolBasa SundaKiswahiliWikang Filipino
» FM200 Συστήματα Πυροπροστασίας HFC-227EA » Non-piping Cabinet Type FM200 Suppression System for Large Space Fire Prevention

Σύστημα καταστολής τύπου FM200 χωρίς σωληνώσεις για την πρόληψη μεγάλων διαστημικών πυρκαγιών

Cabinet Type FM200 system is a non-piping system for total flooding the hazard, it use the most clean agent HFC-227ea as suppression chemicals, widely installed in power rooms, data rooms, computer rooms etc.

with cabinet over there, then you can install it in the room space, no need for other additional cylinder rooms.

It will not cause any harm to the human body and the environment, it is halon alternative.

 

  • Περιγραφή
  • Χαρακτηριστικά και εφαρμογή
  • Επιπλέον πληροφορίες
  • Άλλες προφυλάξεις

ΓΕΝΙΚΗ ΠΕΡΙΓΡΑΦΗ

Ο παράγοντας πυρόσβεσης αερίου είναι ένας από τους τέσσερις (Νερό, αφρός, ξηρά χημική ουσία και αέριο) παραδοσιακοί πυροσβεστήρες, ανάμεσά τους, HFC-227EA Επταφθοροροπανη έχει εξαιρετικές ιδιότητες καθαριότητας και υψηλής απόδοσης, τώρα έχει γίνει ένας ευρέως χρησιμοποιημένος καθαρός πράκτορας πυρόσβεσης αερίου.

Γιατί αλώνι 1211 και 1301 were phased out because it would destroy the atmospheric ozone layer, μετά από αυτό, HFC-227ea γεννήθηκε, HFC-227ea γίνετε το αλώνι-εναλλακτικό προϊόν και δημοφιλές.

Στη δεκαετία του 1990, Αυτό το σύστημα HFC-227ea FM200 έρχεται στην Κίνα και την Κίνα συστήματα πυρόσβεσης επειδή παράγουν αυτό το προϊόν και το βελτιώνουν, ερευνούμε ένα σύστημα που βασίζεται σε κατοικίες υπουργικού συμβουλίου.

Το σύστημα καταστολής τύπου υπουργικού συμβουλίου FM200 είναι πολύ πιο εύκολο να λειτουργήσει και να εγκατασταθεί από εκείνους το σύνθετο σύστημα σωληνώσεων σε άλλες χώρες, το ονομάσαμε ” Καθαρό σύστημα καταστολής πυρκαγιάς τύπων γραφείων”, Η κύρια χημική ουσία του είναι HFC-227es, έτσι καλέσαμε επίσης ” Σύστημα τύπου υπουργικού συμβουλίου FM200”.

HFC-227ea είναι οι κύριες χημικές ουσίες που χρησιμοποιούνται σε όλο τον κόσμο για την καταστολή πυρκαγιάς και πολύ δημοφιλής, σχεδόν τελείωσε 50% των συστημάτων πυρόσβεσης υιοθετεί HFC-227ea ως κύριο παράγοντα, τόσο φανερά, Το σύστημα καταστολής FM200 είναι το πιο δημοφιλές σύστημα στον κόσμο, Το σύστημα NOVEC1230 εξακολουθεί να μην είναι σε θέση να ταιριάξει μαζί του.

Ένα πλήρες σύστημα επταφθοροροπανίνης αποτελείται από πολλά συστατικά, υπάρχουν: βαλβίδα εμπορευματοκιβωτίων, Κύλινδρος πρακτόρων, Πράκτορας HFC-227EA, Σιφόνι, Συσκευή ανάδρασης σήματος, Ηλεκτρομαγνητική βαλβίδα, εύκαμπτος σωλήνας υψηλής πίεσης, ακροφύσια κ.λπ..

Όταν το σύστημα λειτουργεί, θα πλημμυρίσει εντελώς ολόκληρο το δωμάτιο με ψεκασμό του παράγοντα καταστολής του HFC-227ea, εντός 10 δευτερόλεπτα θα καταστείλει τη φωτιά με επιτυχία, και μετά την εκφόρτιση, το αέριο πυρόσβεσης θα διαλυθεί αυτόματα και θα τρέξει μακριά, και μην αφήσετε υπολείμματα.

Μετά την εγκατάσταση του συστήματος πυρόσβεσης, Βρίσκεται ήδη σε κατάσταση αυτόματης εργασίας, όταν η φωτιά συμβαίνει στους κινδύνους, ανιχνευτής θερμότητας, ανιχνευτής καπνού και άλλα στοιχεία ανίχνευσης θερμοκρασίας θα ελάττωμα πυρκαγιά, και σήμα συναγερμών πυρκαγιάς μεταφοράς στον πίνακα ελέγχου πυρκαγιάς αερίου, Ο Πίνακας Ελέγχου θα στείλει εντολή ενεργοποίησης για να ξεκινήσει η συσκευή καταστολής πυρκαγιάς FM200, και μετά 30 χρονική καθυστέρηση δευτερολέπτων, Η συσκευή καταστολής FM200 θα αρχίσει να καταστέλλει τη φωτιά; ταυτόχρονα, Ο πίνακας ελέγχου θα στείλει σήμα στο στροβοσκόπιο&κέρατο, κουδούνι συναγερμού, προειδοποιητική σήμανση απελευθέρωσης αερίου, για να υπενθυμίσει στους ανθρώπους στον τόπο του εγκλήματος να φύγουν γρήγορα.

ΠΡΟΔΙΑΓΡΑΦΗ ΚΑΙ ΠΑΡΆΜΕΤΡΟς

Ακολουθούν ορισμένες βασικές παράμετροι αυτού του προϊόντος:

  • Όνομα προϊόντος: Σύστημα καταστολής πυρκαγιάς FM200 καθαρών πρακτόρων μη-σωληνώσεων
  • Υπόδειγμα: Στυλ GQQ.
  • Λειτουργία εγκατάστασης: σταθερός τύπος.
  • Πίεση αποθήκευσης: κάτω των 20°C, είναι 2.5 Mpa.
  • Μέγιστη πίεση εργασίας: 4.2 Mpa.
  • Πράκτορας: HFC-227EA.
  • Πυκνότητα γεμίσματος παράγοντα: ≤1120 κιλά ανά κυβικό μέτρο.
  • Μέγεθος κυλίνδρων αποθήκευσης πρακτόρων: 40, 70L, 90L, 100L, 120L, 150L, 180L, σε λίτρα.
  • Ποιότητα αριστερού παράγοντα μετά την απαλλαγή: 0 προς 3 Χιλιόγραμμα.
  • Θερμοκρασία περιβάλλοντος: 0 προς 50 °C.
  • Λειτουργία ενεργοποίησης: ΣΥΝΕΧΈΣ ΡΕΎΜΑ 24 Βολτ και 1.2 Ένας (Ηλεκτρικά έναρξη), ≤150N (Πνευματική έναρξη και μη αυτόματη έναρξη).
  • Χρόνος καθυστέρησης καταστολής: λιγότερο από 30 Δευτερόλεπτα.
  • Χρόνος εκφόρτισης: λιγότερο από 10 Δευτερόλεπτα.
  • Υλικό κυλίνδρων: Χάλυβας άνθρακα αρίστης ποιότητας με στίλβωση και κόκκινη επικάλυψη.
  • Λειτουργία καταστολής πυρκαγιάς: Συνολικές πλημμύρες.
  • Κατηγορία πυρόσβεσης: Στερεά φωτιά, Υγρή φωτιά, Φωτιά αερίου, Ηλεκτρική φωτιά.
  • Εκτελεστικό Πρότυπο: GB16670-2006, ΕΣΠΑ, ΟΥΛ.

ΕΓΧΕΙΡΊΔΙΟ ΕΓΚΑΤΆΣΤΑΣΗς

Για περισσότερες λεπτομέρειες σχετικά με αυτό το προϊόν, διαβάστε ΤΟ ΕΓΧΕΙΡΊΔΙΟ ΕΓΚΑΤΆΣΤΑΣΗς ΤΟΥ ΓΡΑΦΕΊΟΥ ΤΎΠΟΥ FM200 προσεχτικά.

 

ΧΑΡΑΚΤΗΡΙΣΤΙΚΆ

  • Not require any cylinder storage rooms to place this system.
  • Can install in a single protection room seperately.
  • Easy to install and operate.
  • HFC-227ea is a clean agent, not cause any pollution to the environment, επιπλέον, not have any bad affect on human body.
  • It can completely work with gas fire alarm systems.

ΕΦΑΡΜΟΓΈΣ

  • Computer Room.
  • Server Room.
  • Switchgear Room.
  • Control Room.
  • UPS Battery Room.
  • Energy Storage System Room.
  • Power Supply Room and Power Plant.
  • Substation.
  • Academy.
  • Water Treatment Plant.
  • Generator Room.
  • Libraries, Museums and Archives.
  • Data Center.
  • Bus Station, Train Station, Airport and Seaport.
  • Communication Base Station.
  • Bank Vault.
  • TV Broadcasting Center.
  • Research and development building.
  • Paint room.
  • Chemical warehouse.
  • Waste water treatment station.
  • Oil Depot etc.

INSTALLATIN

Please do installation as per below point:

  • The cabinet must be placed at the site marked in gas suppression drawings of protection area, and the cabinet is suggested to install near wall, it is also necessary to ensure that the cabinet is stable without shaking and lean.
  • The bottle group of extinguishing agent must be moved to the center of cabinet, its frond side must face the outward direction, and it also must be fixed on the cabinet by using hoops and hooks, be careful and not crush the cabinet.
  • The nozzle must be installed at the nozzle hole at the top of the cabinet, the discharging must be carried out at outward direction against the cabinet, the inner part must be fixed on the cabinet by using clamp nuts.
  • The joint of high-pressure hose with elbow must be installed on the outlet thread of container valve and be screwed down using wrench, the other side must be connected to the thread at the nozzle end.
  • After debugged, the pressure signal device must be installed at the relevant interface of high-pressure hose.
  • The gas pressure gauge must be installed at the interface container valve.
  • The electromagnetic actuator (valve) must be installed on the container valve of gas storage bottle; as for double bottle group, the electromagnetic actuator must be installed at the container valve of driving storage bottle and the pneumatic actuator must also must be installed at the container valve of driving storage bottle.
  • In the installation of double-bottle group start-up pipeline, the container valve of driving bottle and the pheumatic actuator of driven bottle must be connected. this part can not be installed in the event that the deviation in distance between two bottle groups. At this moment, it is necessary to adjust the location of two bottle groups slightly.
  • Lines of pressure signal device and electromagnetic actuator must be traversed through the reserved thread hole behind the cabinet and connected to the gas fire control panel or control center. pay attention to use the protection tube in order to avoid damaging to the lines.
  • Each part which has been installed and connected must be checked again and again. it is necessary to ensure the firm fixing, good connection and sealing of pipeline and correct line connection, therefore, the installation of the whole set of cabinet type HFC-227ea fire suppression equipment is completed.

 

SYSTEM DEBUGGING

Do this system debugging as per the following:

  • Start-up test of electromagnetic actuator, take down the electromagnetic actuator, plug out the safety pin and connect the 24VDC test power, test the operation of the electromagnet linkage switch blade. after the test, the switch blade and safety pin in the electromagnetic actuator must be reset.
    Attention: Debugging of the electromagnetic actuator must be independently conducted without the container valve.
  • Test of storage pressure: unscrew the nut behind the pressure gauge in the counter-clockwise manner until it shows, the indicator in green area means normal state. After the test, remember to tighten the nut, in order to ensure that the pressure gauge will not damaged or leaked because of long-term under high pressure.
  • Feedback signal simulation: two lead wires of the short circle pressure signal device simulate the discharging feedback signals.
  • Debugging of gas fire control panel: Conduct automatic, manual and emergency start-up/stop debugging, be subjected to requirements of the Specifications of Gas Extinguishing System Construction and Acceptance.
  • After the qualified debugging job is well done, the electromagnetic actuator must be installed on the container valve of extinguishing agent carefully. The pressure signal device must be installed on the relevant interface of high-pressure hose and connected to the signal feedback line.
  • After the completion of the acceptance by the fire department and training of the user organization, the start-up lines of the electromagnetic actuator must be connected. plug out the safety pin of the electromagnetic actuator, the equipment must be in formal operation.

Έντυπο Έρευνας ( θα σας επιστρέψουμε το συντομότερο δυνατό. )

Όνομα:
*
Email:
*
Μήνυμα:

Εξακρίβωση:
5 + 9 = ?

Ίσως σου αρέσει επίσης.

  • ΓΙΑΤΙ ΝΑ ΜΑς ΔΙΑΛΈΞΕΤΕ

    Είμαστε ένα ISO 9001, ISO14001, ISO18001 ο πιστοποιημένος κατασκευαστής ειδικεύεται στο σύστημα πυρόσβεσης για μια δεκαετία ετών, χρησιμοποιούμε την κορυφαία ποιότητα του υλικού για να παραγάγουμε τα προϊόντα και όλοι τους έχουν περάσει αυστηρά την επιθεώρηση QC πρίν αφήνουν το εργοστάσιο, τα περισσότερα από τα προϊόντα μας έχουν πιστοποιητικά και approvlas του CE, RHOS, IP67, GL, Κινεζική γλώσσα της έκθεσης δοκιμής από το ίδρυμα της Κίνας.

  • ΕΠΙΚΟΙΝΩΝΉΣΤΕ ΜΑΖΊ ΜΑς

    Jiangxi επίγνωση της Co. τεχνολογίας πυρκαγιάς, ΕΠΕ

    Διεύθυνση: Αριθμός 112, Περιφέρεια Γιουσούι, Πόλη Ξινιού, Επαρχία Τζιανγκξί, Δημοκρατία της Κίνας.

    Τηλ: 0086-0790-6000119
    Φαξ: 0086-0790-6001119
    Ηλεκτρονικό ταχυδρομείο: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com