China Top Ten Enterprise sa Fire Protection at Seguridad Industriya
EnglishবাংলাБългарскиΕλληνικάItalianoLatīnaLatviešu valodaLietuvių kalbaPortuguêsRomânăSlovenčinaEspañolBasa SundaKiswahiliWikang Filipino
» FM200 Fire Protection Systems HFC-227EA » Non-piping Cabinet Type FM200 Suppression System for Large Space Fire Prevention

Non-piping Gabinete Uri FM200 Suppression System para sa Malaking Space Fire Prevention

Cabinet Type FM200 system is a non-piping system for total flooding the hazard, it use the most clean agent HFC-227ea as suppression chemicals, widely installed in power rooms, data rooms, computer rooms etc.

with cabinet over there, then you can install it in the room space, no need for other additional cylinder rooms.

It will not cause any harm to the human body and the environment, it is halon alternative.

 

  • Deskrip
  • Mga Tampok at Application
  • Karagdagang Impormasyon
  • Iba pang mga Pag iingat

PANGKALAHATANG PAGLALARAWAN

Gas sunog extinguishing ahente ay isa sa apat na (tubig, foam, tuyo kemikal at gas) tradisyunal na sunog extinguishing ahente, sa kanila, HFC-227EA Heptafluoropropane ay may mahusay na katangian kalinisan at mataas na kahusayan, ngayon ito ay naging isang malawak na ginagamit na malinis na apoy ng gas extinguishing ahente.

Dahil halon 1211 at 1301 ay phased out dahil ito ay sirain ang atmospheric ozone layer, pagkatapos niyon, HFC-227ea ay ipinanganak, HFC-227ea maging ang halon-alternatibong produkto at popular na.

Noong 1990s, ito HFC-227ea FM200 sistema ay dumating sa Tsina at China sunog sistema dahil gumawa ng produktong ito at mapabuti ito, pananaliksik out ng isang gabinete pabahay batay sistema.

Gabinete uri FM200 suppression system ay mas madaling upang mapatakbo at i-install kaysa sa mga kumplikadong sistema ng pinggan sa ibang bansa, pinangalanan namin ito ” Gabinete Uri Malinis Agent Fire Suppression System”, nito pangunahing kemikal ay HFC-227es, kaya tinatawag din naming ” Gabinete Uri FM200 System”.

HFC-227ea ay ang pangunahing kemikal na ginagamit sa buong mundo para sa sunog suppression at napaka-tanyag, halos higit sa 50% ng sunog sistema ng pagpigil sistema pinagtibay HFC-227ea bilang pangunahing ahente, kaya malinaw na, ang FM200 suppression system ay ang pinaka-popular na sistema sa mundo, NOVEC1230 sistema pa rin hindi pa rin magagawang tumugma sa kanya.

Ang isang kumpletong heptafluoropropane system ay binubuo ng maraming mga bahagi, may mga: lalagyan balbula, Ahente cylinder, HFC-227EA Agent, Siphon, Signal Feedback Device, Electromagnetic Valve, mataas na presyon ng hose, nozzles atbp.

Kapag gumagana ang sistema, ito ay kabuuang pagbaha sa buong kuwarto sa pamamagitan ng pag-spray out suppression ahente ng HFC-227ea, sa loob ng 10 segundo ito ay suppressed sunog matagumpay, at pagkatapos ng discharging, ang extinguishing gas ay dissiped awtomatikong at tumakbo palayo, at huwag mag-iwan ng walang natitira.

Pagkatapos ng extinguishing system ay naka-install, ito ay sa awtomatikong nagtatrabaho katayuan, kapag apoy ay nangyayari sa mga panganib, init detector, usok detector at iba pang mga temperatura sensing elemento ay defected apoy, at transportasyon alarma signal sa gas sunog control panel, ang control panel ay magpapadala ng out aktibasyon order upang simulan ang FM200 sunog suppression aparato, at pagkatapos ng 30 segundo oras pagkaantala, ang FM200 suppression aparato ay magsisimulang suppression apoy; kasabay nito, ang control panel ay magpapadala ng signal sa strobe&sungay, alarma bell, gas release babala signage, upang ipaalala sa mga tao sa tanawin upang iwanan mabilis.

PAGTUTUKOY AT PARAMETER

Nasa ibaba ang ilang mga pangunahing parameter ng produktong ito:

  • Pangalan ng Produkto: Non-ping Malinis Ahente Gabinete FM200 Fire Suppression System
  • Modelo: GQQ estilo.
  • Modong instalasyon: naayos na tipo.
  • Imbakan presyon: sa ilalim ng 20°C, ito ay 2.5 Mpa.
  • Pinakamataas na nagtatrabaho presyon: 4.2 Mpa.
  • Ahente: HFC-227EA.
  • Ahente punan ang density: ≤120 kilo bawat kubiko metro.
  • Ahente imbakan laki: 40, 70L, 90L, 100L, 120L, 150L, 180L, sa liters.
  • Kaliwang ahente kalidad pagkatapos ng discharge: 0 sa 3 kilo.
  • Ambient temperatura: 0 sa 50 °C.
  • Modong Aktibasyon: D at T 24 Bolta at 1.2 A (Electrically magsimula), ≤150N (Pneumatic magsimula at Simulang Manwal).
  • Suppression pagkaantala oras: mas mababa kaysa sa 30 segundo.
  • Oras ng pag-discharg: mas mababa kaysa sa 10 segundo.
  • Cylinder materyales: Mataas na grado carbon bakal na may buli at pulang patong.
  • Sunog suppression mode: Kabuuang Pagbaha.
  • Sunog Suppression Class: Solidong sunog, Likido apoy, sunog sa gas, Electrical Sunog.
  • Ehekutibong Pamantayan: GB16670-2006, NFPA, UL.

Mag-instala ng manwal

Para sa karagdagang mga detalye tungkol sa produktong ito mangyaring basahin ANG MANWAL NG PAG-INSTALL NG GABINETE URI FM200 maingat na.

 

MGA TAMPOK

  • Not require any cylinder storage rooms to place this system.
  • Can install in a single protection room seperately.
  • Easy to install and operate.
  • HFC-227ea is a clean agent, not cause any pollution to the environment, karagdagang, not have any bad affect on human body.
  • It can completely work with gas fire alarm systems.

MGA APLIKASYON

  • Computer Room.
  • Server Room.
  • Switchgear Room.
  • Control Room.
  • UPS Battery Room.
  • Energy Storage System Room.
  • Power Supply Room and Power Plant.
  • Substation.
  • Academy.
  • Water Treatment Plant.
  • Generator Room.
  • Libraries, Museums and Archives.
  • Data Center.
  • Bus Station, Train Station, Airport and Seaport.
  • Communication Base Station.
  • Bank Vault.
  • TV Broadcasting Center.
  • Research and development building.
  • Paint room.
  • Chemical warehouse.
  • Waste water treatment station.
  • Oil Depot etc.

INSTALLATIN

Please do installation as per below point:

  • The cabinet must be placed at the site marked in gas suppression drawings of protection area, and the cabinet is suggested to install near wall, it is also necessary to ensure that the cabinet is stable without shaking and lean.
  • The bottle group of extinguishing agent must be moved to the center of cabinet, its frond side must face the outward direction, and it also must be fixed on the cabinet by using hoops and hooks, be careful and not crush the cabinet.
  • The nozzle must be installed at the nozzle hole at the top of the cabinet, the discharging must be carried out at outward direction against the cabinet, the inner part must be fixed on the cabinet by using clamp nuts.
  • The joint of high-pressure hose with elbow must be installed on the outlet thread of container valve and be screwed down using wrench, the other side must be connected to the thread at the nozzle end.
  • After debugged, the pressure signal device must be installed at the relevant interface of high-pressure hose.
  • The gas pressure gauge must be installed at the interface container valve.
  • The electromagnetic actuator (valve) must be installed on the container valve of gas storage bottle; as for double bottle group, the electromagnetic actuator must be installed at the container valve of driving storage bottle and the pneumatic actuator must also must be installed at the container valve of driving storage bottle.
  • In the installation of double-bottle group start-up pipeline, the container valve of driving bottle and the pheumatic actuator of driven bottle must be connected. this part can not be installed in the event that the deviation in distance between two bottle groups. At this moment, it is necessary to adjust the location of two bottle groups slightly.
  • Lines of pressure signal device and electromagnetic actuator must be traversed through the reserved thread hole behind the cabinet and connected to the gas fire control panel or control center. pay attention to use the protection tube in order to avoid damaging to the lines.
  • Each part which has been installed and connected must be checked again and again. it is necessary to ensure the firm fixing, good connection and sealing of pipeline and correct line connection, therefore, the installation of the whole set of cabinet type HFC-227ea fire suppression equipment is completed.

 

SYSTEM DEBUGGING

Do this system debugging as per the following:

  • Start-up test of electromagnetic actuator, take down the electromagnetic actuator, plug out the safety pin and connect the 24VDC test power, test the operation of the electromagnet linkage switch blade. after the test, the switch blade and safety pin in the electromagnetic actuator must be reset.
    Attention: Debugging of the electromagnetic actuator must be independently conducted without the container valve.
  • Test of storage pressure: unscrew the nut behind the pressure gauge in the counter-clockwise manner until it shows, the indicator in green area means normal state. After the test, remember to tighten the nut, in order to ensure that the pressure gauge will not damaged or leaked because of long-term under high pressure.
  • Feedback signal simulation: two lead wires of the short circle pressure signal device simulate the discharging feedback signals.
  • Debugging of gas fire control panel: Conduct automatic, manual and emergency start-up/stop debugging, be subjected to requirements of the Specifications of Gas Extinguishing System Construction and Acceptance.
  • After the qualified debugging job is well done, the electromagnetic actuator must be installed on the container valve of extinguishing agent carefully. The pressure signal device must be installed on the relevant interface of high-pressure hose and connected to the signal feedback line.
  • After the completion of the acceptance by the fire department and training of the user organization, the start-up lines of the electromagnetic actuator must be connected. plug out the safety pin of the electromagnetic actuator, the equipment must be in formal operation.

Form ng Pagtatanong ( kami ay bumalik sa iyo sa lalong madaling panahon )

Pangalan:
*
Email:
*
Mensahe:

Verification:
3 + 9 = ?

Siguro gusto mo rin

  • BAKIT TAYO PINIPILI

    Kami ay ISANG ISO 9001, ISO14001, ISO18001 sertipiko tagagawa dalubhasa sa fire suppression system para sa isang dekada ng taon, gamitin namin ang tuktok kalidad ng materyal upang makabuo ng mga produkto at ang lahat ng mga ito ay may mahigpit na inspeksyon QC bago umalis pabrika, karamihan sa aming mga produkto ay may nakuha sertipiko at approvlas ng CE, RHOS, IP67, GL, Wikang Tsino ng Test Report mula sa China Institute.

  • MAKIPAG-UGNAY SA AMIN

    Jiangxi Kamalayan Fire Teknolohiya Co, Ltd

    Adres: Numero 112, Yushui District, Lungsod ng Xinyu, Lalawigan ng Jiangxi, Republika ng Tsina.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com