Non-piping Gabinete Uri FM200 Suppression System para sa Malaking Space Fire Prevention

Cabinet Type FM200 system is a non-piping system for total flooding hazard, it uses the cleanest agent HFC-227ea as suppression chemicals, are widely installed in power rooms, mga silid ng data, computer kuwarto, atbp.

may cabinet na dun, tapos pwede mo na i install sa room space, hindi na kailangan ng iba pang mga karagdagang silindro room.

Hindi ito magdudulot ng anumang pinsala sa katawan ng tao at sa kapaligiran, it is a halon alternative.

 

  • Deskrip
  • Mga Tampok at Application
  • Karagdagang Impormasyon
  • Iba pang mga Pag iingat

PANGKALAHATANG PAGLALARAWAN

Gas sunog extinguishing ahente ay isa sa apat na (tubig, foam, dry chemical, and gas) tradisyunal na sunog extinguishing ahente, sa kanila, HFC-227EA Heptafluoropropane has excellent properties cleanliness, and high efficiency, ngayon ito ay naging isang malawak na ginagamit na malinis na apoy ng gas extinguishing ahente.

Dahil halon 1211 at 1301 were phased out because they would destroy the atmospheric ozone layer, HFC-227ea ay ipinanganak, and HFC-227ea became the halon-alternative product and popular.

Noong 1990s, this HFC-227ea FM200 system came into China and China fire suppression systems because produced this product and improved it, we researched a cabinet housing-based system.

Cabinet type FM200 suppression system is much easier to operate and install than those complex piping systems in other countries, pinangalanan namin ito ” Gabinete Uri Malinis Agent Fire Suppression System”, nito pangunahing kemikal ay HFC-227es, so we also called it ” Gabinete Uri FM200 System”.

HFC-227ea is the main chemical that is used all over the world for fire suppression and is very popular, almost 50% of fire suppression systems adopt HFC-227ea as the main agent, kaya malinaw na, the FM200 suppression system is the most popular in the world, NOVEC1230 sistema pa rin hindi pa rin magagawang tumugma sa kanya.

A complete hepta-fluoropropane system consists of many components, there are container valve, Ahente cylinder, HFC-227EA Agent, Siphon, Signal Feedback Device, Electromagnetic Valve, mataas na presyon ng hose, nozzles, atbp.

Kapag gumagana ang sistema, it will flood the whole room by spraying out the suppression agent of HFC-227ea, sa loob ng 10 segundo ito ay suppressed sunog matagumpay, and after discharge, ang extinguishing gas ay dissiped awtomatikong at tumakbo palayo, at huwag mag-iwan ng walang natitira.

Pagkatapos ng extinguishing system ay naka-install, ito ay sa awtomatikong nagtatrabaho katayuan, kapag apoy ay nangyayari sa mga panganib, init detector, usok detector, and other temperature sensing elements will defect fire, and transport the fire alarm signal to the gas fire control panel, ang control panel ay magpapadala ng out aktibasyon order upang simulan ang FM200 sunog suppression aparato, at pagkatapos ng 30 segundo oras pagkaantala, ang FM200 suppression aparato ay magsisimulang suppression apoy; kasabay nito, ang control panel ay magpapadala ng signal sa strobe&sungay, alarma bell, gas release babala signage, upang ipaalala sa mga tao sa tanawin upang iwanan mabilis.

PAGTUTUKOY AT PARAMETER

Nasa ibaba ang ilang mga pangunahing parameter ng produktong ito:

  • Pangalan ng Produkto: Non-ping Malinis Ahente Gabinete FM200 Fire Suppression System
  • Modelo: GQQ estilo.
  • Modong instalasyon: naayos na tipo.
  • Imbakan presyon: sa ilalim ng 20°C, ito ay 2.5 Mpa.
  • Pinakamataas na nagtatrabaho presyon: 4.2 Mpa.
  • Ahente: HFC-227EA.
  • Ahente punan ang density: ≤1120 kilograms per cubic meter.
  • Ahente imbakan laki: 40, 70L, 90L, 100L, 120L, 150L, 180L, sa liters.
  • Kaliwang ahente kalidad pagkatapos ng discharge: 0 sa 3 kilo.
  • Ambient temperatura: 0 sa 50 °C.
  • Modong Aktibasyon: D at T 24 Bolta at 1.2 A (Electrically magsimula), ≤150N (Pneumatic magsimula at Simulang Manwal).
  • Suppression pagkaantala oras: mas mababa kaysa sa 30 segundo.
  • Oras ng pag-discharg: mas mababa kaysa sa 10 segundo.
  • Cylinder materyales: High-grade carbon steel with polishing and red coating.
  • Sunog suppression mode: Kabuuang Pagbaha.
  • Sunog Suppression Class: Solidong sunog, Likido apoy, sunog sa gas, Electrical Sunog.
  • Ehekutibong Pamantayan: GB16670-2006, NFPA, UL.

MANWAL SA PAG-INSTALL

Para sa karagdagang mga detalye tungkol sa produktong ito mangyaring basahin ANG MANWAL NG PAG-INSTALL NG GABINETE URI FM200 maingat na.

 

MGA TAMPOK

  • Hindi nangangailangan ng anumang mga silid ng imbakan ng silindro upang ilagay ang sistemang ito.
  • Can install in a single protection room separately.
  • Madaling i install at patakbuhin.
  • HFC-227ea ay isang malinis na ahente, does not cause any pollution to the environment, and does not have any bad effects on the human body.
  • Maaari itong ganap na gumana sa mga sistema ng alarma ng sunog ng gas.

MGA APLIKASYON

  • Computer Room.
  • Server Room.
  • Switchgear Room.
  • Control Room.
  • Silid ng Baterya ng UPS.
  • Silid ng System ng Imbakan ng Enerhiya.
  • Power Supply Room at Power Plant.
  • Substation.
  • Akademya.
  • Halaman ng Paggamot ng Tubig.
  • Generator Room.
  • Mga Aklatan, Mga Museo at Archive.
  • Data Center.
  • Istasyon ng Bus, Istasyon ng Tren, Paliparan at Seaport.
  • Istasyon ng Base ng Komunikasyon.
  • Bank Vault.
  • TV Broadcasting Center.
  • Pagbuo ng pananaliksik at pag unlad.
  • Pintura ng kuwarto.
  • Bodega ng kemikal.
  • Wastewater treatment station.
  • Oil Depot atbp.

INSTALLATION

Please do the installation as per the below point:

  • The cabinet must be placed at the site marked in gas suppression drawings of the protection area, and the cabinet is suggested to be installed near the wall, kailangan din siguraduhin na stable ang cabinet na walang pagyanig at paghilig.
  • The bottle group of extinguishing agent must be moved to the center of the cabinet, ang frond side nito ay dapat harapin ang panlabas na direksyon, at kailangan din itong ayusin sa cabinet sa pamamagitan ng paggamit ng hoops at hooks, ingat at wag durugin ang cabinet.
  • Ang nozzle ay dapat na naka install sa butas ng nozzle sa tuktok ng cabinet, the discharging must be carried out in an outward direction against the cabinet, and the inner part must be fixed on the cabinet by using clamp nuts.
  • The joint of the high-pressure hose with the elbow must be installed on the outlet thread of the container valve and be screwed down using a wrench, yung kabilang side dapat connected sa thread sa nozzle end.
  • Pagkatapos ng debugged, the pressure signal device must be installed at the relevant interface of the high-pressure hose.
  • Ang gas pressure gauge ay dapat na naka install sa balbula ng lalagyan ng interface.
  • Ang electromagnetic actuator (balbula) must be installed on the container valve of the gas storage bottle; as for the double bottle group, the electromagnetic actuator must be installed at the container valve of the driving storage bottle and the pneumatic actuator must also be installed at the container valve of driving storage bottle.
  • In the installation of a double-bottle group start-up pipeline, the container valve of the driving bottle and the pneumatic actuator of the driven bottle must be connected. this part can not be installed if the a deviation in distance between two bottle groups. Sa sandaling ito, it is necessary to adjust the location of the two bottle groups slightly.
  • Ang mga linya ng presyon ng signal device at electromagnetic actuator ay dapat na traversed sa pamamagitan ng nakareserbang butas ng thread sa likod ng cabinet at konektado sa gas fire control panel o control center. pay attention to using the protection tube to avoid damaging the lines.
  • Each part that has been installed and connected must be checked again and again. ito ay kinakailangan upang matiyak ang firm pag aayos, good connection and sealing of pipeline, and correct line connection, kaya nga, ang pag-install ng buong hanay ng mga cabinet type HFC-227ea fire suppression equipment ay nakumpleto.

PAG DEBUG NG SYSTEM

Gawin ang system debugging na ito bilang bawat ang mga sumusunod:

  • Start-up test of an electromagnetic actuator, ibaba ang electromagnetic actuator, plug out ang safety pin at ikonekta ang 24VDC test power, test the operation of the electromagnet linkage switchblade. pagkatapos ng pagsusulit, the switchblade and safety pin in the electromagnetic actuator must be reset.
    Pansin: Ang pag debug ng electromagnetic actuator ay dapat na independiyenteng isinasagawa nang walang balbula ng lalagyan.
  • Pagsubok ng presyon ng imbakan: unscrew the nut behind the pressure gauge in a counter-clockwise manner until it shows, ang tagapagpahiwatig sa berdeng lugar ay nangangahulugan ng normal na estado. Pagkatapos ng pagsusulit, tandaan na higpitan ang mani, to ensure that the pressure gauge will not damaged or leak because of long-term under high pressure.
  • Simulation ng signal ng feedback: dalawang lead wires ng maikling bilog presyon signal aparato simulate ang discharging feedback signal.
  • Pag debug ng gas fire control panel: Magsagawa ng awtomatikong, manual, and emergency start-up/stop debugging, sumailalim sa mga kinakailangan ng mga Pagtutukoy ng Gas Extinguishing System Construction at Pagtanggap.
  • Matapos ang kwalipikadong debugging job ay mahusay na tapos na, the electromagnetic actuator must be installed on the container valve of the extinguishing agent carefully. The pressure signal device must be installed on the relevant interface of the high-pressure hose and connected to the signal feedback line.
  • Matapos ang pagkumpleto ng pagtanggap ng departamento ng sunog at pagsasanay ng organisasyon ng gumagamit, ang mga linya ng pagsisimula ng electromagnetic actuator ay dapat na konektado. plug out ang safety pin ng electromagnetic actuator, ang mga kagamitan ay dapat na sa pormal na operasyon.

Form ng Pagtatanong ( kami ay bumalik sa iyo sa lalong madaling panahon )

Pangalan:
*
Email:
*
Mensahe:

Verification:
1 + 3 = ?

Siguro gusto mo rin

  • BAKIT TAYO PINIPILI

    Kami ay ISANG ISO 9001, ISO14001, ISO18001 sertipiko tagagawa dalubhasa sa fire suppression system para sa isang dekada ng taon, gamitin namin ang tuktok kalidad ng materyal upang makabuo ng mga produkto at ang lahat ng mga ito ay may mahigpit na inspeksyon QC bago umalis pabrika, karamihan sa aming mga produkto ay may nakuha sertipiko at approvlas ng CE, RHOS, IP67, GL, Wikang Tsino ng Test Report mula sa China Institute.

  • MAKIPAG-UGNAY SA AMIN

    Jiangxi Kamalayan Fire Teknolohiya Co, Ltd

    Adres: Numero 112, Yushui District, Lungsod ng Xinyu, Lalawigan ng Jiangxi, Republika ng Tsina.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com