Computer Room Server Rack Aerosol Sistema di prevenzione incendi

Floor standing aerosol chemical-based fire prevention system is the ideal solution for any enclosure space with an area of 30 A 2000 metri cubi, Per esempio, if a computer room or sever rack room is in a size of 10*8*4 Metri, then several sets of this device would be able to install in the corner of the room as a fire suppression solution.

In case the space is below 30 metri cubi, then another series of MINISOL aerosol will be the best solution; in case space is below 1 cubic meter, then we suggest the Lithium-ion Battery style Aerosol.

  • Descrizione
  • Caratteristiche e applicazione
  • Informazioni aggiuntive
  • Altre precauzioni

INFORMAZIONI DI BASE

There is an aerosol fire prevention system that looks like an air conditioner, it can stand on the floor and does not require any installation.

It is even a halon alternative and HFC-227ea alternative in some special fields, such as small computer rooms, rack per server, telecommunication rooms, and other enclosure spaces.

Floor standing aerosol is an advanced environmentally friendly product with advanced technology, è l'ultimo aerosol di terza generazione di tipo S.

Aerosol technology comes from the rocket technology of the Russian Army, and then some Russian high-tech companies produced the first generation aerosol system, Jiangxi Aware Fire Technology Co., Ltd was the first to import the aerosol technology from Russia, e migliorato la loro tecnologia per formare il nostro China Unique aerosol-Strontium Nitrate Based, which is much more environment-friendly and human friendly than that of Potassium Nitrate Based Aerosol.

Il tipo da pavimento è solo avviamento elettrico, ma può essere in grado di avere un feedback del segnale, di seguito spiegheremo le sue caratteristiche e i suoi dati.

SPECIFICHE E PARAMETRI

In the following, we list our the main technical parameters:

  • Tipo di prodotto: Tipo di pavimento in piedi o a terra.
  • Modello: AW-QRR5LW/S, AW-QRR7,5 LW/S, AW-QRR8LW/S, AW-QRR10LW/S.
  • Stile di attivazione: Avviamento elettrico.
  • Volume di copertina: Da 35 m3 a 71 m3 ·.
  • Tempo di scarico: meno di 120 Secondi.
  • Grandezza: Vedi il MANUALE DI INSTALLAZIONE.
  • Temperatura: da -20°C a +55°C.
  • Umidità relativa: ≤98%.
  • Efficienza di estinzione effettiva: 130-150 grammi per metro cubo.
  • Temperatura della superficie del cilindro: meno di 100°C.
  • Color of the Cylinder: argento bianco e/o rosso.
  • Temperatura del beccuccio: meno di 180°C (5mm distance from the spout.)
  • Stile del segnale di feedback: Apertura normale.
  • Corrente di avvio nominale: 1 A 1.2 Un.
  • Tensione di avvio: Corrente continua: 3 A 24 volts; Corrente alternata: 3 A 240 volts.
  • Durata della vita: 7 A 10 anni.
  • Tipo di soppressione degli incendi: Un, B, C, E.
  • Modalità di installazione: Staffa con viti; e magnetico con colla 3M.
  • Attrezzature di supporto: Sistemi di allarme antincendio.

It mainly applies in those enclosed spaces where the volume ranges from 30 A 2000 metri cubi, Per esempio: sale computer, power generator rooms, and other spaces.

TRATTI SOMATICI

An old technician in our workshop designed this style of aerosol device, which is similar to an external machine air conditioner, His design was inspired by air conditioning, and we all admire him.

To get back to the point, the features are as follows:

  • It should be installed in an enclosure space, not in an open area.
  • It should be used in spaces ranging from 30 A 2000 metri cubi, and over 2000m3 you would better use an FM200 fire protection system.
  • It is a clean product, do not worry that it will do any damage to your machinery and equipment.
  • It leaves no residue after spraying and does not require you to sweep the room.
  • It has a special cooling technology, so when it releasing the aerosol outlet temperature is not very hot.
  • It is a non-piping system, and do not worry about the problem of leakage.
  • Life spans over 7 A 10 anni, and during its service time, people do not need to do any maintenance on it.
  • Pass the fire test and inspection test from China's official research institute, and get a CE certificate for approval.
  • Do not require you to install it with any tools, just place it on the floor in the room.

APPLICAZIONI

  • High-rise Buildings.
  • Power Distribution Room.
  • Library Room.
  • Archives Room.
  • Reference Room.
  • Storage Room.
  • Telecommunication Room.
  • Computer Rooms.
  • Communication Stations.
  • Railway Stations.
  • Distribution Ark.
  • Data Processing.
  • Remote Control.
  • Train Locomotive.
  • High Mobile Equipment Machine Room.
  • Signal Station Room.
  • Data Base Room.

RESTRICTED APPLICATION

This device not be able to apply in the following fields:

  • Chemical substances which can be oxidized rapidly without air.
  • Active Metal.
  • Spontaneous Combustion Substance.
  • Metal Hydroxide.
  • Strong Oxidant.

ATTENTION FOR PRODUCT INSTALLATION

  • The installation job should be done by a professional person or skilled technician.
  • The device is better installed near the wall.
  • The device should not be installed near the wind, vents, door, window, or other opening outlet.
  • Do not install it in a place where easy to get rain and water.
  • Do not install it near the source of the fire flame.
  • Do not install it in the evacuation exit.
  • Do not install it in a place where easy to get shocked, impacted, and corrosion.
  • Mechanical ventilation equipment should be set at an underground pipe gallery or place without windows.
  • The device's activation wire better uses twisted pair wire or dual-core metal shielded wire and the wire size is 1.5 mm2.

ATTENTION FOR USE

Please read our instruction manual carefully before installation.

  • The job of installation and system commissioning must be done by skilled personnel.
  • Dopo l'installazione, do not move the device easily.
  • In case of fire, personnel at the site should leave immediately, and before leaving please close the doors and windows as possible as you can.
  • The life span of this device is 7 years normally, after the service lifetime, please consider replacing it with a new one.
  • Dopo il rilascio, don't touch the cylinder, because it is too hot, after cooling down please wear gloves to move it.
  • In case of any accident, please do not dismantle the device without permission from the manufacturer or authorized agent.
  • The standby power of the fire alarm system is forbidden to charge continuously for 24 orario, and the standby power should be replaced every 4 anni.
  • The inspector should check the fire alarm system yearly and keep a record but do not need to check this device yearly.
  • Before put in use, the installer should make sure that the power is off, in case any device is activated by mistake.

TRASPORTO E STOCCAGGIO

  • Handle with care during its transportation.
  • Store the device in a ventilated and dry warehouse.

SERVIZIO POST-VENDITA

  • Tempo di garanzia: 1 A 2 years based on manufacturing date.
  • Any technician questions or doubts please feel free to inquire from us.
  • After the sale, we can teach you how to install and how to do system debugging.

Modulo ( ti risponderemo il prima possibile )

Nome:
*
E-mail:
*
Messaggio:

Verifica:
4 + 5 = ?

Forse ti piace anche

  • PERCHE' SCEGLIERCI

    Siamo un ISO 9001, Certificazione ISO14001, Produttore certificato ISO18001 specializzato in sistemi antincendio da un decennio di anni, utilizziamo materiale di alta qualità per produrre i prodotti e tutti hanno superato rigorosamente l'ispezione QC prima di lasciare la fabbrica, la maggior parte dei nostri prodotti hanno ottenuto certificati e approvazioni CE, RHOS, IP67 ·, GL, Rapporto di lingua cinese del test del China Institute.

  • CONTATTACI

    Jiangxi Aware Fire Technology Co., Ltd

    Indirizzo: Numero 112, Distretto di Yushui, Xinyu Città, Provincia di Jiangxi, Repubblica di Cina.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    Posta elettronica: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com