Cina Top Ten Imprese nel settore della protezione antincendio e della sicurezza
EnglishবাংলাБългарскиΕλληνικάItalianoLatīnaLatviešu valodaLietuvių kalbaPortuguêsRomânăSlovenčinaEspañolBasa SundaKiswahiliWikang Filipino
» Aerosol Chemical Sistemi automatici antincendio » Computer Room Server Rack Aerosol Fire Prevention System

Computer Room Server Rack Aerosol Sistema di prevenzione incendi

Floor standing aerosol chemical based fire prevention system is ideal solution for any enclosure space with area of 30 A 2000 metri cubi, Per esempio, if a computer room or sever rack room is in a size of 10*8*4 Metri, then several sets of this device would be able to install in the corner of the room as a fire suppression solution.

In case the space is below 30 metri cubi, then another series of MINISOL aerosol will be the best solution; in case space is below 1 cubic meter, then we suggest the Lithium-ion Battery style Aerosol.

  • Descrizione
  • Caratteristiche e applicazione
  • Informazioni aggiuntive
  • Altre precauzioni

INFORMAZIONI DI BASE

C'è un sistema di prevenzione incendi aerosol che sembra un condizionatore d'aria, può stare sul pavimento e non richiede alcuna installazione.

È anche un'alternativa all'halon e all'alternativa HFC-227ea in alcuni campi speciali, come: piccola sala computer, rack per server, sala di telecomunicazione e altro.

L'aerosol da pavimento è un prodotto ecologico avanzato con tecnologia avanzata, è l'ultimo aerosol di terza generazione di tipo S.

La tecnologia aerosol deriva dalla tecnologia missilistica dell'esercito russo, e poi alcune aziende high-tech russe producono il sistema di aerosol di prima generazione, noi Jiangxi Aware Fire Technology Co., Ltd sono i primi a importare la tecnologia aerosol dalla Russia, e migliorato la loro tecnologia per formare il nostro China Unique aerosol-Strontium Nitrate Based, che è molto più rispettoso dell'ambiente e dell'uomo rispetto a quello dell'aerosol a base di nitrato di potassio.

Il tipo da pavimento è solo avviamento elettrico, ma può essere in grado di avere un feedback del segnale, di seguito spiegheremo le sue caratteristiche e i suoi dati.

SPECIFICHE E PARAMETRI

Di seguito elenchiamo i principali parametri tecnici:

  • Tipo di prodotto: Tipo di pavimento in piedi o a terra.
  • Modello: AW-QRR5LW/S, AW-QRR7,5 LW/S, AW-QRR8LW/S, AW-QRR10LW/S.
  • Stile di attivazione: Avviamento elettrico.
  • Volume di copertina: Da 35 m3 a 71 m3 ·.
  • Tempo di scarico: meno di 120 Secondi.
  • Grandezza: Vedi il MANUALE DI INSTALLAZIONE.
  • Temperatura: da -20°C a +55°C.
  • Umidità relativa: ≤98%.
  • Efficienza di estinzione effettiva: 130-150 grammo per metro cubo.
  • Temperatura della superficie del cilindro: meno di 100°C.
  • Colore del cilindro: argento bianco e/o rosso.
  • Temperatura del beccuccio: meno di 180°C (5mm di distanza dal beccuccio.)
  • Stile del segnale di feedback: Apertura normale.
  • Corrente di avvio nominale: 1 A 1.2 Un.
  • Tensione di avvio: Corrente continua: 3 A 24 volt; Corrente alternata: 3 A 240 volt.
  • Durata della vita: 7 A 10 anni.
  • Tipo di soppressione degli incendi: Un, B, C, E.
  • Modalità di installazione: Staffa con viti; e magnetico con colla 3M.
  • Attrezzature di supporto: Sistemi di allarme antincendio.

Si applica principalmente in quegli spazi chiusi in cui il volume è compreso tra 30 A 2000 metri cubi, Per esempio: sale computer, sale generatori di energia e altri spazi.

TRATTI SOMATICI

An old technician in our workshop design out this style of aerosol device, which is similar like a external machine of air conditioner, His design was inspired by air conditioning, we all admire him.

Get back to the point, the features as follow:

  • It should be installed in enclosure space, not in open area.
  • It should use in those space range from 30 A 2000 metri cubi, and over 2000m3 you would better use a FM200 fire protection system.
  • It is clean product, do not worry about that it will do any damage to your machinery and equipment.
  • It leaves no residue after spraying, do not require you to sweep the room.
  • It is with a special cooling technology, so when it releasing the aerosol outlet temperature is not very hot.
  • It is a non-piping system, and do not worry about the problem of leakage.
  • Life span over 7 A 10 anni, and during its service time, people do not need to do any maintenance on it.
  • Pass the fire test and inspection test from China official research institute, and get CE certificate for approval.
  • Do not require you to install it with any tools, just place it on the floor in the room.

APPLICAZIONI

  • High-rise Buildings.
  • Power Distribution Room.
  • Library Room.
  • Archives Room.
  • Reference Room.
  • Storage Room.
  • Telecommunication Room.
  • Computer Rooms.
  • Communication Stations.
  • Railway Stations.
  • Distribution Ark.
  • Data Processing.
  • Remote Control.
  • Train Locomotive.
  • High Mobile Equipment Machine Room.
  • Signal Station Room.
  • Data Base Room.

RESTRICTED APPLICATION

This device not be able to apply in the following fields:

  • Chemical Substance which can be oxidized rapidly without air.
  • Active Metal.
  • Spontaneous Combustion Substance.
  • Metal Hydroxide.
  • Strong Oxidant.

ATTENTION FOR PRODUCT INSTALLATION

  • The installation job should be done by a professional person or skilled technician.
  • The device better installed near the wall.
  • The device should not be installed near wind, vent, door, window and other opening outlet.
  • Do not install it in a place where easy to get rain and water.
  • Do not install it near source of fire flame.
  • Do not install in evacuation exit.
  • Do not install it in a place where easy to get shocked, impacted and corrosion.
  • Mechanical ventilation equipment should be set at a underground pipe gallery or place without windows.
  • The device's activation wire better use twisted pair wire, or use dual-core metal shielded wire and the wire size better is 1.5 mm2.

ATTENTION FOR USE

Please read our instruction manual carefully before installation.

  • The job of installation and system commissioning must be done by a skilled personnel.
  • After installation, do not move the device easily.
  • In case of fire, personnel at site should leave immediately, and before leave please close the doors and windows as possible as you can.
  • The life span of this device is 7 years normally, after the service life time, please consider to replace it with a new one.
  • Dopo il rilascio, don't touch the cylinder, because it is too hot, after cool down please wear gloves to move it.
  • In case of any accident, please do not dismantle the device without permission from the manufacturer or authorized agent.
  • The standby power of fire alarm system is forbidden to charge continuously for 24 orario, and the standby power should be replaced every 4 anni.
  • The inspector should check the fire alarm system yearly and keep record, but do not need to check this device yearly.
  • Before put in use, the installer should make sure that the power is off, in case of any device activated by mistake.

TRANSPORTATION AND STORAGE

  • Handle with care during its transportation.
  • Store the device at a ventilated and dry warehouse.

SERVIZIO POST-VENDITA

  • Tempo di garanzia: 1 A 2 years based on manufacturing date.
  • Any technician question and doubt please feel free to inquiry from us.
  • After sale we can teach you how do install and how to do system debugging.

Modulo ( ti risponderemo il prima possibile )

Nome:
*
E-mail:
*
Messaggio:

Verifica:
2 + 3 = ?

Forse ti piace anche

  • PERCHE' SCEGLIERCI

    Siamo un ISO 9001, Certificazione ISO14001, Produttore certificato ISO18001 specializzato in sistemi antincendio da un decennio di anni, utilizziamo materiale di alta qualità per produrre i prodotti e tutti hanno superato rigorosamente l'ispezione QC prima di lasciare la fabbrica, la maggior parte dei nostri prodotti hanno ottenuto certificati e approvazioni CE, RHOS, IP67 ·, GL, Rapporto di lingua cinese del test del China Institute.

  • CONTATTACI

    Jiangxi Aware Fire Technology Co., Ltd

    Indirizzo: Numero 112, Distretto di Yushui, Xinyu Città, Provincia di Jiangxi, Repubblica di Cina.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    Posta elettronica: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com