Cina Top Ten Imprese nel settore della protezione antincendio e della sicurezza
EnglishবাংলাБългарскиΕλληνικάItalianoLatīnaLatviešu valodaLietuvių kalbaPortuguêsRomânăSlovenčinaEspañolBasa SundaKiswahiliWikang Filipino
» Sistemi antincendio a polvere secca superfine stile ABC » Impulse Powder Fire Extinguisher for Car and Bus Engine Compartment
  • Estintore a polvere ad impulsi per vano motore auto e autobus

    Super-fine ABC dry Chemical powder fire extinguisher for is a product with a long history, mainly apply in engine compartment of bus, car, truck, vessel etc,

    it suppress fire quickly, just need 3 A 5 Secondi.

    • Descrizione
    • Caratteristiche e applicazioni
    • Informazioni aggiuntive
    • Altre precauzioni

    Estintori a polvere ad impulsi sono prodotti chimici secchi super-fini, sono principalmente per il vano motore di navi e veicoli, vano batteria e rallentatore, installati nelle loro aree dove facile da ottenere runaway termico, Questo prodotto ha una certa resistenza agli urti capacità, adatto a qualsiasi ambiente di lavoro cattivo, può mettere fuori classe A, B, C, E incendi.

    Questo tipo di estintore può completare automaticamente il processo dalla ricerca allo spegnimento di un incendio, sicuro ed efficiente, facile da installare e utilizzare, basta installarlo nella posizione designata nel veicolo, quando scoppia un incendio nel motore, il gruppo di avviamento trasferisce rapidamente l'incendio al dispositivo di estinzione, e il dispositivo antincendio si avvierà automaticamente.

    Può anche essere attivato con un interruttore di avvio preinstallato, Aprire la casella dei pulsanti, premere il coperchio protettivo interno in plastica rossa per avviare l'estintore a polvere.

    Ha 2 modalità di attivazione, uno è l'attivazione termica, un altro è l'attivazione elettrica

    ATTIVAZIONE TERMICA

    Quando prendi una fiamma libera, o rilevamento di una temperatura del fuoco di 175°C, Le filo termico sarà acceso, e quindi l'estintore verrà attivato.

    ATTIVAZIONE ELETTRICA

    Dopo aver rilevato la temperatura del fuoco, l'allarme sonoro e luminoso agirà, L'interruttore manuale di allarme è installato nell'area di guida, in caso di emergenza, il conducente può attivare il dispositivo antincendio dalla cabina, Realizza l'effetto del controllo della temperatura e del controllo elettrico.

    Il prodotto è costituito da polvere secca ABC super-fine, coprire, diaframma di tenuta, presa dedicata, componenti di attivazione( termico ed elettrico), pulsante di controllo start e dispositivo di feedback del segnale.

    Ha i seguenti parametri e scheda tecnica:

    • Modello: FFX-ACD0.3/0.4/0.5
    • Agente estinguente: 0.3, 0.4, 0.5 Chilogrammi.
    • Dimensione: diametro 165*80mm(165*100millimetro).
    • Tasso di concentrazione: 127 grammo per metro cubo.
    • Volume di protezione: gamma da 2 A 5 metri cubi.
    • Tempo di spegnimento: meno di 5 Secondi.
    • Resistenza all'avviamento elettrico: 2.4 A 5 Ω.
    • Tensione di funzionamento: DC6-24 V.
    • Corrente di attivazione:meno di 0.5 A e più di 0.3 Un.
    • Corrente di sicurezza: ≤0,5 A.
    • Modalità di attivazione: filo elettrico e termico.
    • Allarme di rilevamento temperatura: 120±5°C.
    • Temperatura di attivazione della linea termica: 175±10°C.
    • Temperatura: -40 a +90°C.
    • Modello di connettore del filo del dispositivo: 282104-1.
    • Modello di specifica del filo di controllo: NH-II.A-RVV-300/500-2×0.5-GA306.2-2007.

     

    TRATTI SOMATICI

    This product have features that similar to our Minisol Aerosol Fire Extinguisher, Ci sono:

    • Small volume.
    • Fully functional.
    • Easy to install.
    • Have function of manual start, automatic start and signal feedback.
    • Comply with requirements of GB7258-2012 and international standards.
    • Reliable quality and low price.
    • Waterproof, moisture proof, freeze proof, and not require any pressurized cylinder to load.
    • Good sealing and anti-vibration.
    • Long service life, and in line with ISO vibration standard for vehicle fire extinguishers.

    APPLICAZIONI

    It mainly used for the following fields:

    • Vehicle engine compartment, such as bus, car.
    • Vessel engine room.
    • Battery compartment.
    • Retarder.
    • Generator room.
    • Distribution cabinet.
    • Charging pile.
    • Cable trench and cable tunnel.
    • Archives.

     

    INSTRUCTIONS FOR USE AND MAINTENANCE

    When the driver and occupant find and confirm the fire in the engine compartment, open the cover of the starter controller box which located in the cab, Press the red start button hardly to start the fire extinguisher to put out the fire(attention: There are two miniature buttons under the red launch button board, Only by pressing at the same time, the fire extinguishing device can be activated, otherwise the fire extinguishing device will not be activated); Do not open engine compartment doors and covers before and after extinguishing a fire, Because the fire extinguishing effect is better in closed space.

    Drivers and passengers should inspect the fire extinguisher regularly, iof the aluminum foil at the nozzle of the fire extinguishing device is damaged, the screws of the fire extinguishing device are loose, and the wiring is disconnected, it should be replaced and repaired in time.

    Avoid open flame and high temperature operation to avoid mis-operation; when disassembling and assembling the fire extinguishing device, please ask the professional person who know about this device.

    TRANSPORT AND STORAGE

    • Handle with care when transporting.
    • Throwing is strictly prohibited.
    • Prevent collision.
    • Avoid exposure to sunlight and rain.
    • Storage warehouses require ventilation, dryness and cleanliness.
    • The height should not exceed 6 layers.

    EXPIRATION DATE

    The warranty period for this fire extinguishing device is 2 anni, and life span is 5 A 10 anni, after the expiration date, please contact your local dealer or manufacturer, we will replace at a discounted price.

    AFTER SALES SERVICE

    Our company has an after-sales service department, and has established quality and after-sales tracking service files, Free replacement if the product has quality problems.

     

    INSTALLATION PRECAUTIONS

    • Open flame and with electricity must be avoided during installation.
    • This device must use the nominal working pressure and current.
    • Regularly check the fire extinguishing device. If the fire extinguishing device is damaged or has been sprayed, the fire extinguishing device must be replaced in time.

    Temperature control(thermal cord 175℃) installation precautions

    The jet of the fire extinguisher needs to be aimed at the engine and fixed firmly, Thermal wires are routed around the engine, The thermal line and the fire extinguisher should be 15 cm away from the engine.

    Electric control installation precautions

    • Should be power off to operate.
    • Open flame work is prohibited.
    • The thermal line should be more than 15 cm away from the high temperature part of the engine, Otherwise, the temperature is high in summer, and it is easy to start.
    • Please operate according to the wiring diagram of the fire extinguishing device, Otherwise, the wrong line may be connected.
    • During the debugging process, please use a multi-meter to confirm the electric start terminal and feedback terminal; do the wire connection job after confirming it is correct, Please read the installation manual carefully before wiring.

    Modulo ( ti risponderemo il prima possibile )

    Nome:
    *
    E-mail:
    *
    Messaggio:

    Verifica:
    3 + 4 = ?

    Forse ti piace anche

  • PERCHE' SCEGLIERCI

    Siamo un ISO 9001, Certificazione ISO14001, Produttore certificato ISO18001 specializzato in sistemi antincendio da un decennio di anni, utilizziamo materiale di alta qualità per produrre i prodotti e tutti hanno superato rigorosamente l'ispezione QC prima di lasciare la fabbrica, la maggior parte dei nostri prodotti hanno ottenuto certificati e approvazioni CE, RHOS, IP67 ·, GL, Rapporto di lingua cinese del test del China Institute.

  • CONTATTACI

    Jiangxi Aware Fire Technology Co., Ltd

    Indirizzo: Numero 112, Distretto di Yushui, Xinyu Città, Provincia di Jiangxi, Repubblica di Cina.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    Posta elettronica: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com