» FM200 Sistemi di protezione antincendio HFC-227EA » Non-piping Cabinet Type FM200 Suppression System for Large Space Fire Prevention

Sistema di soppressione dell'armadio non tubazione tipo FM200 per la prevenzione degli incendi in grandi spazi

Cabinet Type FM200 system is a non-piping system for total flooding the hazard, it use the most clean agent HFC-227ea as suppression chemicals, widely installed in power rooms, data rooms, computer rooms etc.

with cabinet over there, then you can install it in the room space, no need for other additional cylinder rooms.

It will not cause any harm to the human body and the environment, it is halon alternative.

 

  • Descrizione
  • Caratteristiche e applicazione
  • Informazioni aggiuntive
  • Altre precauzioni

DESCRIZIONE GENERALE

L'agente estinguente a gas è uno dei quattro (Acqua, schiuma, prodotti chimici e gas secchi) agenti estinguenti tradizionali, tra questi, HFC-227EA Eptafluoropropano ha proprietà eccellenti pulizia e alta efficienza, ora è diventato un agente estinguente a gas pulito ampiamente utilizzato.

Perché l'halon 1211 e 1301 sono stati gradualmente eliminati perché avrebbero distrutto lo strato di ozono atmosferico, dopo di che, Nasce HFC-227ea, HFC-227ea diventa il prodotto alternativo all'halon e popolare.

Negli anni 1990, questo sistema HFC-227ea FM200 entra in Cina e cina sistemi antincendio perché producono questo prodotto e lo migliorano, ricerchiamo un sistema basato sull'alloggiamento dell'armadio.

Il sistema di soppressione FM200 di tipo cabinet è molto più facile da usare e installare rispetto a quei complessi sistemi di tubazioni in altri paesi, l'abbiamo chiamato ” Tipo di armadio Clean Agent Fire Suppression System”, la sua sostanza chimica principale è HFC-227es, così abbiamo anche chiamato ” Sistema FM200 tipo di armadio”.

HFC-227ea è la principale sostanza chimica che viene utilizzata in tutto il mondo per la soppressione degli incendi e molto popolare, quasi finito 50% dei sistemi antincendio adotta HFC-227ea come agente principale, quindi ovviamente, il sistema di soppressione FM200 è il sistema più popolare al mondo, Il sistema NOVEC1230 non è ancora in grado di corrispondere con lui.

Un sistema completo di eptafluoropropano è costituito da molti componenti, Ci sono: valvola contenitore, Cilindro agente, Agente HFC-227EA, Sifone, Dispositivo di feedback del segnale, Valvola elettromagnetica, tubo flessibile ad alta pressione, ugelli ecc.

Quando il sistema funziona, allagherà completamente l'intera stanza spruzzando l'agente di soppressione di HFC-227ea, All'interno 10 secondi sopprimerà il fuoco con successo, e dopo lo scarico, il gas estinguente verrà dissipato automaticamente e scapperà via, e non lasciare residui.

Dopo l'installazione del sistema di spegnimento, è già in stato di funzionamento automatico, quando si verifica un incendio nei pericoli, rilevatore di calore, il rilevatore di fumo e altri elementi di rilevamento della temperatura difettino il fuoco, e segnale di allarme antincendio di trasporto al pannello di controllo antincendio a gas, il pannello di controllo invierà l'ordine di attivazione per avviare il dispositivo antincendio FM200, e dopo 30 ritardo temporale di secondi, Il dispositivo di soppressione FM200 inizierà a sopprimere il fuoco; allo stesso tempo, Il pannello di controllo invierà un segnale allo strobo&corno, campanello d'allarme, segnaletica di avviso di rilascio del gas, per ricordare alle persone sulla scena di andarsene rapidamente.

SPECIFICHE E PARAMETRI

Di seguito sono riportati alcuni parametri di base di questo prodotto:

  • Nome del prodotto: Sistema antincendio FM200 per agenti puliti senza tubazioni
  • Modello: Stile GQQ.
  • Modalità di installazione: tipo fisso.
  • Pressione di stoccaggio: sotto 20°C, Lo è 2.5 Mpa.
  • Pressione massima di esercizio: 4.2 Mpa.
  • Agente: HFC-227EA.
  • Densità di riempimento dell'agente: ≤1120 chilogrammi per metro cubo.
  • Dimensione del cilindro di stoccaggio dell'agente: 40, 70L, 90L, 100L, 120L, 150L, 180L, in litri.
  • Qualità dell'agente sinistro dopo la scarica: 0 A 3 Chilogrammi.
  • Temperatura: 0 A 50 °C.
  • Modalità di attivazione: DC 24 Volt e 1.2 Un (Avviamento elettrico), ≤150N (Avviamento pneumatico e avvio manuale).
  • Tempo di ritardo di soppressione: meno di 30 Secondi.
  • Tempo di scarico: meno di 10 Secondi.
  • Materiale del cilindro: Acciaio al carbonio di alta qualità con lucidatura e rivestimento rosso.
  • Modalità antincendio: Inondazioni totali.
  • Classe antincendio: Fuoco solido, Fuoco liquido, Fuoco a gas, Fuoco elettrico.
  • Standard Esecutivo: GB16670-2006, NFPA, UL.

MANUALE INSTALLATIN

Per maggiori dettagli su questo prodotto si prega di leggere IL MANUALE DI INSTALLAZIONE DEL CABINET TIPO FM200 attentamente.

 

TRATTI SOMATICI

  • Not require any cylinder storage rooms to place this system.
  • Can install in a single protection room seperately.
  • Easy to install and operate.
  • HFC-227ea is a clean agent, not cause any pollution to the environment, inoltre, not have any bad affect on human body.
  • It can completely work with gas fire alarm systems.

APPLICAZIONI

  • Computer Room.
  • Server Room.
  • Switchgear Room.
  • Control Room.
  • UPS Battery Room.
  • Energy Storage System Room.
  • Power Supply Room and Power Plant.
  • Substation.
  • Academy.
  • Water Treatment Plant.
  • Generator Room.
  • Libraries, Museums and Archives.
  • Data Center.
  • Bus Station, Train Station, Airport and Seaport.
  • Communication Base Station.
  • Bank Vault.
  • TV Broadcasting Center.
  • Research and development building.
  • Paint room.
  • Chemical warehouse.
  • Waste water treatment station.
  • Oil Depot etc.

INSTALLATIN

Please do installation as per below point:

  • The cabinet must be placed at the site marked in gas suppression drawings of protection area, and the cabinet is suggested to install near wall, it is also necessary to ensure that the cabinet is stable without shaking and lean.
  • The bottle group of extinguishing agent must be moved to the center of cabinet, its frond side must face the outward direction, and it also must be fixed on the cabinet by using hoops and hooks, be careful and not crush the cabinet.
  • The nozzle must be installed at the nozzle hole at the top of the cabinet, the discharging must be carried out at outward direction against the cabinet, the inner part must be fixed on the cabinet by using clamp nuts.
  • The joint of high-pressure hose with elbow must be installed on the outlet thread of container valve and be screwed down using wrench, the other side must be connected to the thread at the nozzle end.
  • After debugged, the pressure signal device must be installed at the relevant interface of high-pressure hose.
  • The gas pressure gauge must be installed at the interface container valve.
  • The electromagnetic actuator (valve) must be installed on the container valve of gas storage bottle; as for double bottle group, the electromagnetic actuator must be installed at the container valve of driving storage bottle and the pneumatic actuator must also must be installed at the container valve of driving storage bottle.
  • In the installation of double-bottle group start-up pipeline, the container valve of driving bottle and the pheumatic actuator of driven bottle must be connected. this part can not be installed in the event that the deviation in distance between two bottle groups. At this moment, it is necessary to adjust the location of two bottle groups slightly.
  • Lines of pressure signal device and electromagnetic actuator must be traversed through the reserved thread hole behind the cabinet and connected to the gas fire control panel or control center. pay attention to use the protection tube in order to avoid damaging to the lines.
  • Each part which has been installed and connected must be checked again and again. it is necessary to ensure the firm fixing, good connection and sealing of pipeline and correct line connection, therefore, the installation of the whole set of cabinet type HFC-227ea fire suppression equipment is completed.

 

SYSTEM DEBUGGING

Do this system debugging as per the following:

  • Start-up test of electromagnetic actuator, take down the electromagnetic actuator, plug out the safety pin and connect the 24VDC test power, test the operation of the electromagnet linkage switch blade. after the test, the switch blade and safety pin in the electromagnetic actuator must be reset.
    Attenzione: Debugging of the electromagnetic actuator must be independently conducted without the container valve.
  • Test of storage pressure: unscrew the nut behind the pressure gauge in the counter-clockwise manner until it shows, the indicator in green area means normal state. After the test, remember to tighten the nut, in order to ensure that the pressure gauge will not damaged or leaked because of long-term under high pressure.
  • Feedback signal simulation: two lead wires of the short circle pressure signal device simulate the discharging feedback signals.
  • Debugging of gas fire control panel: Conduct automatic, manual and emergency start-up/stop debugging, be subjected to requirements of the Specifications of Gas Extinguishing System Construction and Acceptance.
  • After the qualified debugging job is well done, the electromagnetic actuator must be installed on the container valve of extinguishing agent carefully. The pressure signal device must be installed on the relevant interface of high-pressure hose and connected to the signal feedback line.
  • After the completion of the acceptance by the fire department and training of the user organization, the start-up lines of the electromagnetic actuator must be connected. plug out the safety pin of the electromagnetic actuator, the equipment must be in formal operation.

Modulo ( ti risponderemo il prima possibile )

Nome:
*
E-mail:
*
Messaggio:

Verifica:
4 + 5 = ?

Forse ti piace anche

  • PERCHE' SCEGLIERCI

    Siamo un ISO 9001, Certificazione ISO14001, Produttore certificato ISO18001 specializzato in sistemi antincendio da un decennio di anni, utilizziamo materiale di alta qualità per produrre i prodotti e tutti hanno superato rigorosamente l'ispezione QC prima di lasciare la fabbrica, la maggior parte dei nostri prodotti hanno ottenuto certificati e approvazioni CE, RHOS, IP67 ·, GL, Rapporto di lingua cinese del test del China Institute.

  • CONTATTACI

    Jiangxi Aware Fire Technology Co., Ltd