Unpressurized Super-fine ABC dry powder fire extinguishing devices are non-dangerous goods, that we use to suppress many kinds of fires, in international shipping, we always call it a "Safety device", because it is a product for people's safety.

  • Descrizione
  • Caratteristiche e applicazioni
  • Informazioni aggiuntive
  • Altre precauzioni

INTRODUZIONE

The unpressurized super-fine ABC dry powder extinguishing safety device uses propellant as the driving medium to make the device start to extinguish the fire, it is made up of a carbon dioxide cylinder, agente antincendio chimico secco ABC super-fine, a propellant, film di alluminio, generatore di gas, staffa di installazione, testa di chiusura, guarnizione, activation wire, and so on.

It uses propellant as driving gas to make the ABC dry powder run out of the storage cylinder and suppress the fire, it not only total flooding but also direct-to-source local application; not only for enclosure space but also for open area fire protection.

Di seguito sono riportati i parametri di base e la scheda tecnica:

  • Stile: Tipo non pressurizzato.
  • Agente estinguente: Polvere chimica secca ABC super-fine.
  • Modelli: AW-FFX-ACT2,5, AW-FFX-ACT 3, AW-FFX-ACT5, AW-FFX-ACT8, AW-FFX-ACT10. (per i modelli dettagliati, fare riferimento a www.awarefire.com).
  • Qualità chimica: 2.5 Chilogrammi, 3 Chilogrammi, 5 Chilogrammi, 8 Chilogrammi, 10 Chilogrammi.
  • Attivazione volt: DC 3 A 24 V (0.3 A a 0.5 Un).
  • Temperatura di attivazione: 68°C regolabile.
  • Temperatura termica: 175°C (if required).
  • Volume totale delle inondazioni: Da 20 A 100 metri cubi, per i dettagli fare riferimento al nostro Manuale di installazione.
  • Tempo di spegnimento effettivo: meno di 10 Secondi.
  • Temperatura di esercizio: -40 a +50°C.
  • Umidità relativa: ≤95%.
  • Spegnimento Forza di reazione e tempo: 1.6KN/12ms, 1.8kn/13ms, 2.2kn/15ms, 2.6kn/18ms.
  • Corrente sicura: ≥150mA.
  • Corrente minima di avvio: 220 A 360 mamma.
  • Resistenza: 2.4 A 3.4 ohm.
  • Altezza di installazione: 3.5 A 8.5 Metri.
  • Durata della vita: 5 A 10 anni.
  • Tipo di soppressione degli incendi: Classe A, Classe B, Classe C, Classe E.
  • Standard Esecutivo: GA602-2013 ·.

 

FEATURES AND ADVANTAGES

  • Non-pressurized, Non-blasting, with solid gas driving technology.
  • Intelligent, Automatic startup, Reduces the probability of wrong operation.
  • Non-conductive, non corrosivo, atossico, ODP value is zero, GWP value is zero and ALT value is also zero.
  • Clean product, it is easy to clean up after discharging.
  • Instanoues, instant fire extinguishing, and early restaining.
  • Widely applied in many industries, and especially can be used in frigid zones.
  • Facile da installare e utilizzare, small size, e poco ingombrante.
  • Cost-effective and Economical, without pipeline network and pressurized cylinders.

APPLICAZIONE

  • Switch Rooms.
  • Transformer rooms.
  • Cable Well.
  • Urban Underground Pipe Gallery.
  • Car Garage.
  • Archivio, Biblioteca, Museums.
  • Workplace.
  • magazzino.
  • Insurance rooms.
  • Telecommunication Base station.
  • Sottostazione.
  • Gas Station.
  • Computer Rooms.
  • Modular Data Center Rooms.
  • IT security container.
  • Mobile server room.
  • Server racks.
  • IT security rack.
  • Ring main units.
  • Emergency Power and UPS.

THE DIFFERENCE

Difference between pressurized type and non-pressurized type ABC dry chemical:

  • The pressurized type has pressure to work, and the non-pressurized type without pressure.
  • Pressurized ones cause a little noise voice when it is discharging, but non-pressurized types have little noise.
  • The cost of producing a non-pressurized type is a little higher than that of a pressurized type.
  • The working principle of both of them is different, please refer to the user manual.
  • Pressurized one normally for enclosure space, but non-pressurized one for local application.

ABOUT TRANSPORTATION

  • Take precautions against collisions when transporting.
  • Maneggiare con cura.
  • Protect from sun and rain during transportation.

PRECAUTIONS

  • Do not disassemble this device without permission from the factory.
  • Do not swallow the white inside dry powder fire extinguishing agent.
  • Do not let the children play with it.
  • Only technicians or specially trained professionals can install it.
  • Do the installation and system debugging job as per the INSTALLATION MANUAL.

Modulo ( ti risponderemo il prima possibile )

Nome:
*
E-mail:
*
Messaggio:

Verifica:
2 + 5 = ?

Forse ti piace anche

  • PERCHE' SCEGLIERCI

    Siamo un ISO 9001, Certificazione ISO14001, Produttore certificato ISO18001 specializzato in sistemi antincendio da un decennio di anni, utilizziamo materiale di alta qualità per produrre i prodotti e tutti hanno superato rigorosamente l'ispezione QC prima di lasciare la fabbrica, la maggior parte dei nostri prodotti hanno ottenuto certificati e approvazioni CE, RHOS, IP67 ·, GL, Rapporto di lingua cinese del test del China Institute.

  • CONTATTACI

    Jiangxi Aware Fire Technology Co., Ltd

    Indirizzo: Numero 112, Distretto di Yushui, Xinyu Città, Provincia di Jiangxi, Repubblica di Cina.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    Posta elettronica: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com