Ne vamzdynų spintelės tipo FM200 slopinimo sistema, skirta didelių patalpų gaisro prevencijai

Cabinet Type FM200 system is a non-piping system for total flooding the hazard, it use the most clean agent HFC-227ea as suppression chemicals, widely installed in power rooms, data rooms, computer rooms etc.

with cabinet over there, then you can install it in the room space, no need for other additional cylinder rooms.

It will not cause any harm to the human body and the environment, it is halon alternative.

 

  • Aprašymas
  • Funkcijos ir taikymas
  • Papildoma informacija
  • Kitos atsargumo priemonės

BENDRASIS APRAŠYMAS

Dujų gaisro gesinimo medžiaga yra viena iš keturių (Vanduo, puta, sausos cheminės medžiagos ir dujos) tradiciniai gaisro gesinimo įrenginiai, Tarp jų, HFC-227EA Heptafluoropropane pasižymi puikiomis savybėmis švara ir dideliu efektyvumu, dabar jis tapo plačiai naudojama švarių dujų gaisro gesinimo medžiaga.

Nes halonas 1211 ir 1301 were phased out because it would destroy the atmospheric ozone layer, paskiaus, HFC-227ea gimė, HFC-227ea tapo halono alternatyvaus produkto ir populiarus.

1990-aisiais, ši HFC-227ea FM200 sistema patenka į Kinijos ir Kinijos gaisro gesinimo sistemas, nes gamina šį produktą ir tobulina jį, mes tiriame kabineto būsto sistemą.

Spintelės tipo FM200 slopinimo sistema yra daug lengviau valdoma ir montuojama nei kitose šalyse esanti sudėtinga vamzdynų sistema, Mes jį pavadinome ” Spintelės tipo švarios medžiagos gaisro slopinimo sistema”, Jo pagrindinė cheminė medžiaga yra HFC-227es, Mes taip pat skambinome ” Kabineto tipo FM200 sistema”.

HFC-227ea yra pagrindinės cheminės medžiagos, kurios visame pasaulyje naudojamos gaisrui slopinti ir yra labai populiarios., beveik baigėsi 50% Gaisro gesinimo sistemos HFC-227ea yra pagrindinė agentė, Taigi akivaizdu, kad, FM200 slopinimo sistema yra populiariausia sistema pasaulyje., NOVEC1230 sistema vis dar negali su juo sutapti.

Visa heptafluoropropane sistema susideda iš daugelio komponentų, Yra: konteinerio vožtuvas, Agento cilindras, HFC-227EA agentas, Sifonas, Signalo grįžtamojo ryšio įrenginys, Elektromagnetinis vožtuvas, aukšto slėgio žarna, purkštukai ir kt..

Kai sistema veikia, jis visiškai užtvindys visą kambarį, purškiant HFC-227ea slopinimo agentą, Per 10 Sekundės jis sėkmingai užgniaužs ugnį, ir po iškrovimo, gesinimo dujos bus automatiškai išsklaidytos ir pabėgs, ir nepalikite likučių.

Įrengus gesinimo sistemą, jis jau yra automatinio veikimo būsenoje, Kai gaisras kyla dėl pavojų, šilumos detektorius, dūmų detektorius ir kiti temperatūros jutimo elementai dezertyruos ugnį, ir transportuoti priešgaisrinės signalizacijos signalą į dujų gaisro valdymo skydelį, valdymo pultas išsiųs aktyvinimo užsakymą, kad paleistų FM200 gaisro slopinimo įrenginį, ir po 30 sekundžių vėlavimas, FM200 slopinimo įtaisas pradės slopinti ugnį; tuo pačiu metu, valdymo pultas pasiųs signalą į strobe&ragas, pavojaus varpas, įspėjamieji dujų išleidimo ženklai, Kad žmonės, esantys įvykio vietoje, greitai išvyktų.

SPECIFIKACIJA IR PARAMETRAS

Žemiau yra keletas pagrindinių šio produkto parametrų:

  • Produkto pavadinimas: Ne vamzdynų švaraus agento spintelė FM200 gaisro slopinimo sistema
  • Modelis: GQQ stilius.
  • Diegimo režimas: fiksuotas tipas.
  • Laikymo slėgis: iki 20°C, tai yra 2.5 Mpa.
  • Maksimalus darbinis slėgis: 4.2 Mpa.
  • Agentas: HFC-227EA.
  • Agento užpildymo tankis: ≤1120 kilogramų kubiniame metre.
  • Agento laikymo cilindro dydis: 40, 70L, 90L, 100L, 120L, 150L, 180L, litrais.
  • Kairiojo agento kokybė po išleidimo: 0 į 3 Kilogramų.
  • Aplinkos temperatūra: 0 į 50 °C.
  • Aktyvinimo režimas: DC 24 Voltas ir 1.2 A (Elektrinis paleidimas), ≤150N (Pneumatinė pradžia ir neautomatinis paleidimas).
  • Slopinimo uždelsimo laikas: mažiau nei 30 Sekundžių.
  • Iškrovimo laikas: mažiau nei 10 Sekundžių.
  • Cilindro medžiaga: Aukštos kokybės anglies plienas su poliravimu ir raudona danga.
  • Ugnies slopinimo režimas: Visiškas potvynis.
  • Ugnies slopinimo klasė: Kieta ugnis, Skysta ugnis, Dujų gaisras, Elektros ugnis.
  • Vykdomasis standartas: GB16670–2006 m., NFPA, UL.

INSTALLATIN VADOVAS

Norėdami gauti daugiau informacijos apie šį produktą, skaitykite FM200 TIPO SPINTELĖS MONTAVIMO VADOVAS atsargiai.

 

FUNKCIJOS

  • Not require any cylinder storage rooms to place this system.
  • Can install in a single protection room seperately.
  • Lengva įdiegti ir valdyti.
  • HFC-227ea is a clean agent, not cause any pollution to the environment, be to, not have any bad affect on human body.
  • It can completely work with gas fire alarm systems.

PROGRAMOS

  • Computer Room.
  • Server Room.
  • Switchgear Room.
  • Control Room.
  • UPS Battery Room.
  • Energy Storage System Room.
  • Power Supply Room and Power Plant.
  • Substation.
  • Academy.
  • Water Treatment Plant.
  • Generator Room.
  • Libraries, Museums and Archives.
  • Data Center.
  • Bus Station, Train Station, Airport and Seaport.
  • Communication Base Station.
  • Bank Vault.
  • TV Broadcasting Center.
  • Research and development building.
  • Paint room.
  • Chemical warehouse.
  • Waste water treatment station.
  • Oil Depot etc.

INSTALLATIN

Please do installation as per below point:

  • The cabinet must be placed at the site marked in gas suppression drawings of protection area, and the cabinet is suggested to install near wall, it is also necessary to ensure that the cabinet is stable without shaking and lean.
  • The bottle group of extinguishing agent must be moved to the center of cabinet, its frond side must face the outward direction, and it also must be fixed on the cabinet by using hoops and hooks, be careful and not crush the cabinet.
  • The nozzle must be installed at the nozzle hole at the top of the cabinet, the discharging must be carried out at outward direction against the cabinet, the inner part must be fixed on the cabinet by using clamp nuts.
  • The joint of high-pressure hose with elbow must be installed on the outlet thread of container valve and be screwed down using wrench, the other side must be connected to the thread at the nozzle end.
  • After debugged, the pressure signal device must be installed at the relevant interface of high-pressure hose.
  • The gas pressure gauge must be installed at the interface container valve.
  • The electromagnetic actuator (valve) must be installed on the container valve of gas storage bottle; as for double bottle group, the electromagnetic actuator must be installed at the container valve of driving storage bottle and the pneumatic actuator must also must be installed at the container valve of driving storage bottle.
  • In the installation of double-bottle group start-up pipeline, the container valve of driving bottle and the pheumatic actuator of driven bottle must be connected. this part can not be installed in the event that the deviation in distance between two bottle groups. At this moment, it is necessary to adjust the location of two bottle groups slightly.
  • Lines of pressure signal device and electromagnetic actuator must be traversed through the reserved thread hole behind the cabinet and connected to the gas fire control panel or control center. pay attention to use the protection tube in order to avoid damaging to the lines.
  • Each part which has been installed and connected must be checked again and again. it is necessary to ensure the firm fixing, good connection and sealing of pipeline and correct line connection, therefore, the installation of the whole set of cabinet type HFC-227ea fire suppression equipment is completed.

 

SYSTEM DEBUGGING

Do this system debugging as per the following:

  • Start-up test of electromagnetic actuator, take down the electromagnetic actuator, plug out the safety pin and connect the 24VDC test power, test the operation of the electromagnet linkage switch blade. after the test, the switch blade and safety pin in the electromagnetic actuator must be reset.
    Attention: Debugging of the electromagnetic actuator must be independently conducted without the container valve.
  • Test of storage pressure: unscrew the nut behind the pressure gauge in the counter-clockwise manner until it shows, the indicator in green area means normal state. After the test, remember to tighten the nut, in order to ensure that the pressure gauge will not damaged or leaked because of long-term under high pressure.
  • Feedback signal simulation: two lead wires of the short circle pressure signal device simulate the discharging feedback signals.
  • Debugging of gas fire control panel: Conduct automatic, manual and emergency start-up/stop debugging, be subjected to requirements of the Specifications of Gas Extinguishing System Construction and Acceptance.
  • After the qualified debugging job is well done, the electromagnetic actuator must be installed on the container valve of extinguishing agent carefully. The pressure signal device must be installed on the relevant interface of high-pressure hose and connected to the signal feedback line.
  • After the completion of the acceptance by the fire department and training of the user organization, the start-up lines of the electromagnetic actuator must be connected. plug out the safety pin of the electromagnetic actuator, the equipment must be in formal operation.

Užklausos forma ( mes jus susigrąžinsime kuo greičiau )

Vardas, pavadinimas:
*
El paštas:
*
Pranešimas:

Patikros:
2 + 3 = ?

Galbūt jums taip pat patinka

  • KODĖL VERTA RINKTIS MUS

    Mes esame ISO 9001, ISO14001, ISO18001 sertifikuotas gamintojas jau dešimtmetį specializuojasi gaisro gesinimo sistemoje, mes naudojame aukščiausios kokybės medžiagas, kad galėtume gaminti produktus, ir visi jie prieš išvykdami iš gamyklos praėjo griežtą QC patikrinimą, dauguma mūsų produktų turi CE sertifikatus ir approvlas, RHOS, IP67, GL, Kinijos instituto kinų kalbos testų ataskaita.

  • SUSISIEKITE SU MUMIS

    Jiangxi Aware Fire Technology Co, Ltd

    Adresas: Numeris 112, Yushui rajonas, Xinyu miestas, Dziangsi provincija, Kinijos Respublika.

    Tel: 0086-0790-6000119
    Faksas: 0086-0790-6001119
    El. paštas: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Nuotr.://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com