  • Extintor de incêndio em pó de impulso para compartimento do motor de carro e ônibus

    Super-fine ABC dry Chemical powder fire extinguisher for is a product with a long history, mainly apply in engine compartment of bus, car, truck, vessel etc,

    it suppress fire quickly, just need 3 Para 5 Segundos.

    • Descrição
    • Recursos e Aplicações
    • Informações extras
    • Outras precauções

    Extintores de incêndio em pó de impulso são químico seco super fino, são principalmente para compartimento de motores de navios veículos de anúncio, compartimento de bateria e retarder, instalado em suas áreas onde fácil de obter desgoverno térmico, Este produto tem uma certa resistência ao choque capacidade, adequado para qualquer ambiente de trabalho ruim, pode colocar para fora classe A, B, C, E incêndios.

    Este tipo de extintor de incêndio pode completar automaticamente o processo desde encontrar até extinguir um incêndio, seguro e eficiente, fácil de instalar e usar, só precisa instalá-lo no local designado no veículo, quando um incêndio começa no motor, o conjunto inicial vai transferir rapidamente o fogo para o dispositivo de extinção, e o dispositivo de extinção de fogo será iniciado automaticamente.

    Ele também pode ser ativado com um interruptor de partida pré-instalado, abra a caixa de botão, pressione a tampa de proteção de plástico vermelho interno para iniciar o extintor de fogo em pó.

    Ele tem 2 modo de ativação, um é ativação térmica, outra é a ativação elétrica

    ATIVAÇÃO TÉRMICA

    Quando obter uma chama aberta, ou sentindo uma temperatura de fogo de 175°C, o fio térmico será inflamado, e, em seguida, o extintor de incêndio será ativado.

    ATIVAÇÃO ELÉTRICA

    Depois de sentir a temperatura do fogo, o alarme de som e luz vai agir, Interruptor manual de alarme é instalado na área de condução, em caso de emergência, o motorista pode ativar o dispositivo de extinção de fogo da cabine, Perceba o efeito do controle de temperatura e controle elétrico.

    Produto é composto de pó seco ABC super fino, cobrir, diafragma de vedação, soquete dedicado, componentes de ativação( térmica e elétrica), iniciar botão de controle e dispositivo de feedback de sinal.

    Ele tem os seguintes parâmetros e ficha de dados:

    • Modelo: FFX-ACD0.3/0.4/0.5
    • Agente extintor: 0.3, 0.4, 0.5 Quilogramas.
    • Dimensão: diâmetro 165 * 80mm(165*100milímetro).
    • Taxa de concentração: 127 grama por metros cúbicos.
    • Volume de proteção: variam de 2 Para 5 metros cúbicos.
    • Tempo de extinção: menos do que 5 Segundos.
    • Resistência do início elétrico: 2.4 Para 5 Ω.
    • Tensão de operação: DC6-24 V.
    • Corrente de ativação:menos do que 0.5 A e mais do que 0.3 Um.
    • Corrente de segurança: ≤0.5 A.
    • Modo de ativação: fio elétrico e térmico.
    • Temperatura do alarme de detecção: 120±5°C.
    • Temperatura de ativação da linha térmica: 175±10°C.
    • Temperatura ambiente: -40 a +90°C.
    • Modelo do conector do fio do dispositivo: 282104-1.
    • Modelo de especificação do fio de controle: NH-II.A-RVV-300/500-2×0.5-GA306.2-2007.

     

    FEATURES

    This product have features that similar to our Minisol Aerosol Fire Extinguisher, há:

    • Small volume.
    • Fully functional.
    • Fácil de instalar.
    • Have function of manual start, automatic start and signal feedback.
    • Comply with requirements of GB7258-2012 and international standards.
    • Reliable quality and low price.
    • Waterproof, moisture proof, freeze proof, and not require any pressurized cylinder to load.
    • Good sealing and anti-vibration.
    • Long service life, and in line with ISO vibration standard for vehicle fire extinguishers.

    APPLICATIONS

    It mainly used for the following fields:

    • Vehicle engine compartment, such as bus, car.
    • Vessel engine room.
    • Battery compartment.
    • Retarder.
    • Generator room.
    • Distribution cabinet.
    • Charging pile.
    • Cable trench and cable tunnel.
    • Archives.

     

    INSTRUCTIONS FOR USE AND MAINTENANCE

    When the driver and occupant find and confirm the fire in the engine compartment, open the cover of the starter controller box which located in the cab, Press the red start button hardly to start the fire extinguisher to put out the fire(attention: There are two miniature buttons under the red launch button board, Only by pressing at the same time, the fire extinguishing device can be activated, otherwise the fire extinguishing device will not be activated); Do not open engine compartment doors and covers before and after extinguishing a fire, Because the fire extinguishing effect is better in closed space.

    Drivers and passengers should inspect the fire extinguisher regularly, euf the aluminum foil at the nozzle of the fire extinguishing device is damaged, the screws of the fire extinguishing device are loose, and the wiring is disconnected, it should be replaced and repaired in time.

    Avoid open flame and high temperature operation to avoid mis-operation; when disassembling and assembling the fire extinguishing device, please ask the professional person who know about this device.

    TRANSPORT AND STORAGE

    • Handle with care when transporting.
    • Throwing is strictly prohibited.
    • Prevent collision.
    • Avoid exposure to sunlight and rain.
    • Storage warehouses require ventilation, dryness and cleanliness.
    • The height should not exceed 6 layers.

    EXPIRATION DATE

    The warranty period for this fire extinguishing device is 2 Anos, and life span is 5 Para 10 Anos, after the expiration date, please contact your local dealer or manufacturer, we will replace at a discounted price.

    AFTER SALES SERVICE

    Our company has an after-sales service department, and has established quality and after-sales tracking service files, Free replacement if the product has quality problems.

     

    INSTALLATION PRECAUTIONS

    • Open flame and with electricity must be avoided during installation.
    • This device must use the nominal working pressure and current.
    • Regularly check the fire extinguishing device. If the fire extinguishing device is damaged or has been sprayed, the fire extinguishing device must be replaced in time.

    Temperature control(thermal cord 175℃) installation precautions

    The jet of the fire extinguisher needs to be aimed at the engine and fixed firmly, Thermal wires are routed around the engine, The thermal line and the fire extinguisher should be 15 cm away from the engine.

    Electric control installation precautions

    • Should be power off to operate.
    • Open flame work is prohibited.
    • The thermal line should be more than 15 cm away from the high temperature part of the engine, Otherwise, the temperature is high in summer, and it is easy to start.
    • Please operate according to the wiring diagram of the fire extinguishing device, Otherwise, the wrong line may be connected.
    • During the debugging process, please use a multi-meter to confirm the electric start terminal and feedback terminal; do the wire connection job after confirming it is correct, Please read the installation manual carefully before wiring.

    Formulário de Consulta ( vamos voltar o mais rápido possível )

    Nome:
    *
    Email:
    *
    Mensagem:

    Verificação:
    1 + 5 = ?

    Talvez você também goste.

  • POR QUE NOS ESCOLHER

    Nós somos um ISO 9001, ISO14001, Fabricante certificado ISO18001 especializado em sistema de supressão de incêndio por uma década de anos, usamos a alta qualidade do material para produzir os produtos e todos eles têm passagem estritamente inspeção QC antes de sair da fábrica, a maioria de nossos produtos têm certificados e approvlas de CE, RHOS, IP67, GL, Relatório de língua chinesa do Instituto China.

  • ENTRE EM CONTATO CONOSCO

    Jiangxi Aware Fire Technology Co., Ltd

    Endereço: Número 112, Yushui District, Xinyu City, Jiangxi Province, República da China.

    Tel.: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com