  • Composto de proteção contra incêndio de bateria de íon-lítio

    Extinguishing Chemical-Aerosol Compound, Details refer to our Material Safety Data Sheet, aerosol based is a better lithium-ion batteries fire suppression solution, which is better than BLAZECUT.

    We are the first manufacturer which engage, research and develop aerosol system for lithium battery, we have rich experience to produce them.

    for a complete solution with specific design, please feel free to Contate-nos directly.

     

    • Descrição
    • Recursos e Aplicação
    • Informações extras
    • Outras precauções

    DESCRIÇÃO BÁSICA

    Bateria de lítio é um pequeno elemento elétrico, o que faz com que a maioria dos equipamentos de extinção de fogo no mercado incapaz de combiná-lo, uma empresa chamada BLAZECUT pesquisa um tubo de detecção de incêndio de cor branca que poderia encher com agente HFC-227ea ou NOVEC1230 dentro, mas como seu tamanho é pelo menos diâmetro 18mm * 600mm, parece que também não é uma boa solução para uma proteção de fogo de bateria de íons de lítio tão pequena.

    Até o ano 2020 nosso composto aerossol QRR0.012G/S/SA foi publicado, o problema da proteção contra incêndio para bateria de íons de lítio é bem resolvido.

    QRR0.012G/S/SA é um design espacial para compartimento de íons de lítio, mas também pode se candidatar a algum outro espaço menor estreito, como armário elétrico e caixas DB etc, porque é pequeno o suficiente para ser colocado em uma caixa de bateria de lítio.

    ESPECIFICAÇÕES E PARÂMETROS

    Abaixo listamos algumas das principais fichas técnicas de QRR0.012G/S/SA- solução de aerossol de bateria de lítio:

    • Tipo: QRR0.012G/S/SA (Comentário: 0.007, 0.02, 0.03, 0.04, 0.05, 0.06 também disponível)
    • Tamanho: diâmetro 40 milímetro, e altura de 20 milímetro (De acordo com o Manual de Instalação para QRR0.012G-S-SA).
    • Distância de espaçamento do furo para instalação: φ40.1 * 54.1 mm.
    • Concentração de aerossol: ≤60g por metro cúbico.
    • Volume de proteção: 0.2 metros cúbicos.
    • Tempo de liberação de aerossol: 4 Segundos.
    • Cor do cilindro: Vermelho e outras cores de design especial.
    • Temperatura nominal da linha térmica: 175°C.
    • Comprimento da linha térmica: 0.3 metro (cum ser estendido mediante solicitação do cliente).
    • Comprimento do cabo elétrico: 0.3 metro (pode ser prorrogado conforme a solicitação dos clientes)
    • Corrente de ativação: ≥701 mA (Fornecimento de energia de corrente direta).
    • Corrente de segurança: ≤151mA (Corrente contínua).
    • Tempo de partida elétrica: sobre 1 Segundo.
    • Faixa de temperatura ambiente: -50°C a +95°C.
    • Tempo de vida: 15 Anos.
    • Tempo de garantia: 1 Para 2 Anos.
    • Compatibilidade: ele pode trabalhar com alarme de incêndio e sistema de detecção de incêndio, especialmente pode combinar com painel de alarme de incêndio gasoso.

    OUTRO MODELO SIMILAR DISPONÍVEL:

    Item Altura em mm Diâmetro em mm Volume de proteção em m³ Instalação
    QRR0.007G/S/SA 40.00 20.00 0.1 parafusos explosivos e/ou cola 3M
    QRR0.016G/S/SA 60.00 22.00 0.25 parafusos explosivos e/ou cola 3M
    QRR0.02G/S/SA 60.00 25.50 0.30 parafusos explosivos e/ou cola 3M
    QRR0.03G/S/SA 60.00 25.50 0.50 parafusos explosivos e/ou cola 3M
    QRR0.04G/S/SA 99.00 27.50 0.60 parafusos explosivos e/ou cola 3M
    QRR0.05G/S/SA 99.00 27.50 0.80 parafusos explosivos e/ou cola 3M
    QRR0.06G/S/SA 99.00 27.50 1.00 parafusos explosivos e/ou cola 3M

     

    Clique aqui para ler e baixar MANUAL DE INSTALAÇÃO QRR0.012G/S/SA

    This style of aerosol special design for lithium battery fire protection, as it is small in size, also can be applied in some other enclosure space,

    it has its own particularity.

    CARACTERÍSTICAS

    • Our skilled technician who is over 60 years old special design this product for lithium-ion battery, the product design is handsome and perfect.
    • Aerosol with small dimension, especially the height of aerosol is about 2 centímetro, could be able to install in lithium battery boxes.
    • Aerosol belongs to clean extinguishing compound, it leaves no residue after discharging, its global warming potential value and ozone layer depletion potential value is almost zero, will not damage the components in the lithium battery.
    • Highly concentration, small aerosol quality cover large volume, its light weight and space saving.
    • It could have signal feedback function, and activation function is: thermal plus electric start-up.
    • It can work with a stand-alone trigger device called "THERMAL ACTIVATION DEVICE".

    APLICATIVOS

    • Small vehicles
    • Heavy equipment including: loader, escavadora, tactical assault/riot control, bulldozer.
    • Electric motorcycle.
    • Small electric box.
    • Small electrical products.
    • Lithium-ion batteries.
    • Refrigerator.
    • Washing machine.
    • Air conditioner.
    • Cable connector.
    • 3D printers.
    • Special army and police vehicles.
    • Telecom tower schetters.
    • Ventilation devices.
    • Laser cuttings.

    FIRE SUPPRESSION CLASS

    • Class A fire-Solid Combustibles.
    • Class B fire-Flammable Liquids.
    • Class C fire-Flammable Gases.
    • Class E fire-Electrical Appliances.

    QRR0.012G/S/SA aerosol fire suppression device can suppress fire of Class A, B, C, E rapidly.

    The device is suitable for ambient temperature of -50℃ to +95℃ (in short time can reach +125℃), most suitable for small enclosure space fire protection, such as small electrical cabinet/panel, coffer, lithium battery etc; it belongs to fixed type fire suppression system.

    PRINCÍPIO DE TRABALHO

    When the device get activation signal from the fire control panel or from the thermal cord, the aerosol compound inside the device is activated, then rapidly cause aerosol particles gas and the gas running out from the nozzle(side), to total flooding in the fire protection zone, to suppress the fire.

    ATTENTION FOR TRAMSPORTATON AND STORE.

    • Do not get close to heat source when it is being in transportation, store and installation, please avoid sunlight and rain.
    • Do not use the product when the aerosol device’s outer shell is damaged.
    • Do not disassemble the device without the permission of the manufacturer.
    • People who enter the site must wear gas mask, in case of the aerosol device is being in discharging.

    INSPECTION

    • Please read carefully the installation manual before installation, and check the device and its accessories, install it after confirm of every components are good.
    • Inspection Method:
      • Appearance Inspection: check the appearance of the device, it should not drop paint, no indentation and no deformation, and accessories should be complete.
      • The product has passed strict factory inspection, however, the device and its accessories may be damaged due to various reasons during transportation; so when do installation, it is necessary to inspect each device according to above method.

    INSTALLATION AND MAINTENANCE

    • Take out the installation bracket of the aerosol device and fix it, there should be no obstacles between the aerosol device and the protective objectives. if necessary, the installer can install the auxiliary support also, the auxiliary support should be able to bear at least 5 times the weight of aerosol device, to make sure the aerosol device is firmly installed.
    • When installation, you need to consider avoid high temperature areas above 95℃. there should be no obstacles within 0.1m in diameter of the aerosol device.
    • Do not disassemble the device without the permission of the manufacturer.The thermal cord should be arranged along where the fire perhaps will occurs; it is forbidden to install it at the high temperature pipelines, in case of be activated by mistake.
    • After releasing, the cylinder of aerosol device is super hot with high temperature, so it is forbidden to touch it, wait until it cools down before you can handle it.
    • During its valid time, it is no need to hold yearly quality inspection; The cylinder of the aerosol device needs to be regularly cleaned of dust and dirty according to the actual situations; if it is found to be deformed or damaged, it should be replaced in time; Regularly check wiring for open circuit, short circuit and resistance value of the ignition device and keep records.
    • The related losses caused by abnormal installation, maintenance and use are not within the scope of the company's warranty.

     

    Formulário de Consulta ( vamos voltar o mais rápido possível )

    Nome:
    *
    Email:
    *
    Mensagem:

    Verificação:
    2 + 4 = ?

    Talvez você também goste.

  • POR QUE NOS ESCOLHER

    Nós somos um ISO 9001, ISO14001, Fabricante certificado ISO18001 especializado em sistema de supressão de incêndio por uma década de anos, usamos a alta qualidade do material para produzir os produtos e todos eles têm passagem estritamente inspeção QC antes de sair da fábrica, a maioria de nossos produtos têm certificados e approvlas de CE, RHOS, IP67, GL, Relatório de língua chinesa do Instituto China.

  • ENTRE EM CONTATO CONOSCO

    Jiangxi Aware Fire Technology Co., Ltd

    Endereço: Número 112, Yushui District, Xinyu City, Jiangxi Province, República da China.

    Tel.: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com