Sistema de supressão fm200 tipo de armário não tubulação para prevenção de incêndio de grandes espaços

Cabinet Type FM200 system is a non-piping system for total flooding the hazard, it use the most clean agent HFC-227ea as suppression chemicals, widely installed in power rooms, data rooms, computer rooms etc.

with cabinet over there, then you can install it in the room space, no need for other additional cylinder rooms.

It will not cause any harm to the human body and the environment, it is halon alternative.

 

  • Descrição
  • Recursos e Aplicação
  • Informações extras
  • Outras precauções

DESCRIÇÃO GERAL

Agente de extintor de gás é um dos quatro (Água, espuma, químico seco e gás) agentes tradicionais de extinção de fogo, entre eles, HFC-227EA Heptafluoropropano tem excelente limpeza de propriedades e alta eficiência, agora ele se tornou um agente de extinção de fogo de gás limpo amplamente usado.

Porque halon 1211 e 1301 foram eliminados gradualmente porque destruiria a camada atmosférica de ozônio, depois disso, HFC-227ea nasceu, HFC-227ea se torna o produto alternativo halon e popular.

Na década de 1990, este sistema HFC-227ea FM200 entra nos sistemas de supressão de fogo da China e china porque produz este produto e o melhora, pesquisamos um sistema baseado em habitação gabinete.

Sistema de supressão do tipo armário FM200 é muito mais fácil de operar e instalar do que aqueles complexos sistemas de tubulação em outros países, nós o chamamos de ” Sistema de supressão de fogo do agente limpo do tipo de gabinete”, seu principal produto químico é o HFC-227es, então nós também chamamos ” Sistema FM200 tipo gabinete”.

HFC-227ea é o principal produto químico que é usado em todo o mundo para supressão de fogo e muito popular, quase mais 50% de sistemas de supressão de fogo adota HFC-227ea como agente principal, tão obviamente, o sistema de supressão FM200 é o sistema mais popular do mundo, SISTEMA NOVEC1230 ainda não ser capaz de combinar com ele.

Um sistema completo de heptafluoropropano consiste em muitos componentes, há: válvula de recipiente, Cilindro de agente, Agente HFC-227EA, Sifão, Dispositivo de feedback de sinal, Válvula eletromagnética, mangueira de alta pressão, bicos etc.

Quando o sistema funciona, ele vai inundar toda a sala, pulverizando agente de supressão de HFC-227ea, dentro de 10 segundos ele vai suprimir o fogo com sucesso, e depois de descarregar, o gás extintor será dissipado automaticamente e fugirá, e não deixar nenhum resíduo.

Após a instalação do sistema de extinção, ele já está em status de trabalho automático, quando o fogo acontece nos perigos, detector de calor, detector de fumaça e outros elementos de sensoriamento de temperatura vai desertar fogo, e transportar sinal de alarme de incêndio para o painel de controle de fogo de gás, o painel de controle enviará ordem de ativação para iniciar o dispositivo de supressão de fogo FM200, e depois 30 atraso de tempo segundos, o dispositivo de supressão FM200 começará a suprimir o fogo; ao mesmo tempo, o painel de controle enviará sinal para o estrobo&corno, Alarme, sinalização de aviso de liberação de gás, para lembrar as pessoas na cena para sair rapidamente.

ESPECIFICAÇÃO E PARÂMETRO

Abaixo estão alguns parâmetros básicos deste produto:

  • Nome do produto: Sistema de supressão de fogo do agente limpo não tubulação FM200
  • Modelo: Estilo GQQ.
  • Modo de instalação: tipo fixo.
  • Pressão de armazenamento: abaixo de 20°C, é 2.5 Mpa.
  • Pressão máxima de trabalho: 4.2 Mpa.
  • Agente: HFC-227EA.
  • Densidade de preenchimento de agente: ≤1120 kg por metro cúbico.
  • Tamanho do cilindro de armazenamento do agente: 40, 70L, 90L, 100L, 120L, 150L, 180L, em litros.
  • Qualidade do agente esquerdo após a descarga: 0 Para 3 Quilogramas.
  • Temperatura ambiente: 0 Para 50 °C.
  • Modo de ativação: DC 24 Volt e 1.2 Um (Início eletricamente), ≤150N (Início pneumático e Início Manual).
  • Tempo de atraso de supressão: menos do que 30 Segundos.
  • Tempo de descarregamento: menos do que 10 Segundos.
  • Material do cilindro: Aço carbono de alto grau com polimento e revestimento vermelho.
  • Modo de supressão de fogo: Inundações Totais.
  • Aula de Supressão de Fogo: Fogo sólido, Fogo líquido, Fogo de Gás, Fogo Elétrico.
  • Padrão Executivo: GB16670-2006, NFPA, UL.

INSTALLATIN MANUAL

Para mais detalhes sobre este produto, leia O MANUAL DE INSTALAÇÃO DO TIPO DE ARMÁRIO FM200 cuidadosamente.

 

CARACTERÍSTICAS

  • Not require any cylinder storage rooms to place this system.
  • Can install in a single protection room seperately.
  • Easy to install and operate.
  • HFC-227ea is a clean agent, not cause any pollution to the environment, além disso, not have any bad affect on human body.
  • It can completely work with gas fire alarm systems.

APLICATIVOS

  • Computer Room.
  • Server Room.
  • Switchgear Room.
  • Control Room.
  • UPS Battery Room.
  • Energy Storage System Room.
  • Power Supply Room and Power Plant.
  • Substation.
  • Academy.
  • Water Treatment Plant.
  • Generator Room.
  • Libraries, Museums and Archives.
  • Data Center.
  • Bus Station, Train Station, Airport and Seaport.
  • Communication Base Station.
  • Bank Vault.
  • TV Broadcasting Center.
  • Research and development building.
  • Paint room.
  • Chemical warehouse.
  • Waste water treatment station.
  • Oil Depot etc.

INSTALLATIN

Please do installation as per below point:

  • The cabinet must be placed at the site marked in gas suppression drawings of protection area, and the cabinet is suggested to install near wall, it is also necessary to ensure that the cabinet is stable without shaking and lean.
  • The bottle group of extinguishing agent must be moved to the center of cabinet, its frond side must face the outward direction, and it also must be fixed on the cabinet by using hoops and hooks, be careful and not crush the cabinet.
  • The nozzle must be installed at the nozzle hole at the top of the cabinet, the discharging must be carried out at outward direction against the cabinet, the inner part must be fixed on the cabinet by using clamp nuts.
  • The joint of high-pressure hose with elbow must be installed on the outlet thread of container valve and be screwed down using wrench, the other side must be connected to the thread at the nozzle end.
  • After debugged, the pressure signal device must be installed at the relevant interface of high-pressure hose.
  • The gas pressure gauge must be installed at the interface container valve.
  • The electromagnetic actuator (valve) must be installed on the container valve of gas storage bottle; as for double bottle group, the electromagnetic actuator must be installed at the container valve of driving storage bottle and the pneumatic actuator must also must be installed at the container valve of driving storage bottle.
  • In the installation of double-bottle group start-up pipeline, the container valve of driving bottle and the pheumatic actuator of driven bottle must be connected. this part can not be installed in the event that the deviation in distance between two bottle groups. At this moment, it is necessary to adjust the location of two bottle groups slightly.
  • Lines of pressure signal device and electromagnetic actuator must be traversed through the reserved thread hole behind the cabinet and connected to the gas fire control panel or control center. pay attention to use the protection tube in order to avoid damaging to the lines.
  • Each part which has been installed and connected must be checked again and again. it is necessary to ensure the firm fixing, good connection and sealing of pipeline and correct line connection, therefore, the installation of the whole set of cabinet type HFC-227ea fire suppression equipment is completed.

 

SYSTEM DEBUGGING

Do this system debugging as per the following:

  • Start-up test of electromagnetic actuator, take down the electromagnetic actuator, plug out the safety pin and connect the 24VDC test power, test the operation of the electromagnet linkage switch blade. after the test, the switch blade and safety pin in the electromagnetic actuator must be reset.
    Attention: Debugging of the electromagnetic actuator must be independently conducted without the container valve.
  • Test of storage pressure: unscrew the nut behind the pressure gauge in the counter-clockwise manner until it shows, the indicator in green area means normal state. After the test, remember to tighten the nut, in order to ensure that the pressure gauge will not damaged or leaked because of long-term under high pressure.
  • Feedback signal simulation: two lead wires of the short circle pressure signal device simulate the discharging feedback signals.
  • Debugging of gas fire control panel: Conduct automatic, manual and emergency start-up/stop debugging, be subjected to requirements of the Specifications of Gas Extinguishing System Construction and Acceptance.
  • After the qualified debugging job is well done, the electromagnetic actuator must be installed on the container valve of extinguishing agent carefully. The pressure signal device must be installed on the relevant interface of high-pressure hose and connected to the signal feedback line.
  • After the completion of the acceptance by the fire department and training of the user organization, the start-up lines of the electromagnetic actuator must be connected. plug out the safety pin of the electromagnetic actuator, the equipment must be in formal operation.

Formulário de Consulta ( vamos voltar o mais rápido possível )

Nome:
*
Email:
*
Mensagem:

Verificação:
1 + 4 = ?

Talvez você também goste.

  • POR QUE NOS ESCOLHER

    Nós somos um ISO 9001, ISO14001, Fabricante certificado ISO18001 especializado em sistema de supressão de incêndio por uma década de anos, usamos a alta qualidade do material para produzir os produtos e todos eles têm passagem estritamente inspeção QC antes de sair da fábrica, a maioria de nossos produtos têm certificados e approvlas de CE, RHOS, IP67, GL, Relatório de língua chinesa do Instituto China.

  • ENTRE EM CONTATO CONOSCO

    Jiangxi Aware Fire Technology Co., Ltd

    Endereço: Número 112, Yushui District, Xinyu City, Jiangxi Province, República da China.

    Tel.: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com