    DESCRIÇÃO SOBRE DETECTOR DE FUMAÇA

    O número do modelo do detector de fumaça é: AW-CSD381, seu nome completo é “detector de fumaça foto-eletrônico convencional”, ele usa uma câmara de sensoriamento óptico de última geração, é para proteção de área interna, can work with fire control panel AW-GEC2169 and AW-CFP2166, the detector that initiate the alarm condition will have its red LED and relays latched until reset by the fire control panel.

    Principais parâmetros e ficha técnica:

    • Número do modelo: AW-CSD381.
    • Tamanho: 9.95*9.95*4.82 centímetro.
    • Peso: sobre 115.00 Gramas.
    • Bateria: sem.
    • Tensão principal: 24 VDC ou 12 VDC.
    • Operação atual: status de monitoramento ≤120uA, Estado de alarme ≤15mA.
    • Cablagem: Zona+ e Zona-, a promessa de dois sistema de ônibus.
    • Classe de Proteção: IP 30.
    • Sensibilidade ao alarme de fumaça: 0.1 Para 0.15 dB por metro.
    • Conexão: Não. 5 é entrada de zona+; Não. 6 é entrada de zona -, Não. 2 é a saída de relé NO; Não. 3 é a saída de relé COM.
    • Valor de saída do relé: 0.5A em 24 VDC.
    • Ambiental: Faixa de temperatura classe A de -10 a +50°C.
    • Umidade relativa do ar: ≤95% RH, não condensação.
    • Painel de controle de fogo de acasalamento: AW-CFP2166, AW-GEC2169.
    • Aplicação: para uso interno.

    DESCRIÇÃO NO DETECTOR DE CALOR

    A descrição no detector de calor é quase a mesma do detector de fumaça, a diferença é que o detector de calor é para descobrir fogo, detectando a temperatura nos perigos de incêndio.

    Principais parâmetros e ficha técnica a seguir:

    • Número do item: AW-CTD382.
    • Dimensão: 99.5*99.5*4.82 milímetro.
    • Peso do produto: 100 Gramas.
    • Atributo: Detecção de calor.
    • Conexão: mesmo que detector de fumaça.
    • Saída de relé: 0.5A @24 DC.
    • Corrente de espera: menos de 120uA.
    • A corrente máxima de alarme: menos do que 15 mamã.
    • Condição de fiação: O mesmo que detector de fumaça.
    • Corrigir alarme de temperatura: 57°C A2R.
    • Taxa de alarme de elevação: 7.1°C/5 segundos, A2R.
    • Temperatura ambiente: -10 a +60°C.
    • Umidade relativa do ar: 5% Para 95% RH, não condensação.
    • Cor e Materiais: Plástico ABS branco.
    • Host correspondente: AW-GEC2169, AW-CFP2166.

    Till present, many trading and contracting companies, and construction and engineering companies like to buy from us directly, their projects in need of kinds of fire suppression systems and fire alarm systems according to their project requirement, most of them send us the drawings in .dwg or .pdf to help design for them.

    FEATURES OF SMOKE DETECTOR AW-CSD381

    details as follow:

    • It is photo-electric type spot detector.
    • Built in dual LED's.
    • 360 degree visualization.
    • Remote indicator output.
    • Compatible with any fire alarm system in the market.
    • Surface mounting.
    • Have LED indicator.
    • Completely functional test with every activation.
    • Meet with all requirement for latest standard EN54-7:2018.

    The features of heat detector AW-CTD382 is almost the same as AW-CSD381.

     

    COMPATIBILITY DESCRIPTION

    No matter smoke detector or heat detector, they all belongs to the detection system, they normally work together with fire alarm control panel to form a complete fire alarm system.

    In a fire protection room, both need smoke detectors and heat detectors.

    in case the smoke detector sensing out fire, it will send signal to fire control panel; and if the heat detector find out fire, it also will send signal to the fire control panel, Both of them work together to better identify fires, so that the controller can take measures accurately.

     

    EMBALAGEM, STORAGE AND INSTALLATON

    • Packing them into standard export carton box.
    • To prevent moisture, keep them in a dry and ventilated house.
    • When do installation, do the job of installation strictly as per Instruction Manual, and use standard installation tools.

    PACKAGE SIZE AND WEIGHT

    Carton Quantity: 10 PCS per Box, 10 Boxes per Carton.

    • Box Size: 20.5*23.5*11 centímetro.
    • Carton Size: 43*27*58 centímetro.
    • Peso: 1.42 kilograms per box, e 14.2 kilograms per carton.

    Formulário de Consulta ( vamos voltar o mais rápido possível )

    Nome:
    *
    Email:
    *
    Mensagem:

    Verificação:
    0 + 4 = ?

    Talvez você também goste.

  • POR QUE NOS ESCOLHER

    Nós somos um ISO 9001, ISO14001, Fabricante certificado ISO18001 especializado em sistema de supressão de incêndio por uma década de anos, usamos a alta qualidade do material para produzir os produtos e todos eles têm passagem estritamente inspeção QC antes de sair da fábrica, a maioria de nossos produtos têm certificados e approvlas de CE, RHOS, IP67, GL, Relatório de língua chinesa do Instituto China.

  • ENTRE EM CONTATO CONOSCO

    Jiangxi Aware Fire Technology Co., Ltd

    Endereço: Número 112, Yushui District, Xinyu City, Jiangxi Province, República da China.

    Tel.: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com