Non-conducte cabinet de tip FM200 suprimarea sistemului pentru spațiu mare de prevenire a incendiilor

Cabinet Type FM200 system is a non-piping system for total flooding the hazard, it use the most clean agent HFC-227ea as suppression chemicals, widely installed in power rooms, data rooms, computer rooms etc.

with cabinet over there, then you can install it in the room space, no need for other additional cylinder rooms.

It will not cause any harm to the human body and the environment, it is halon alternative.

 

  • Descriere:__________
  • Caracteristici și aplicații
  • Informații suplimentare
  • Alte precauții

DESCRIERE GENERALĂ

Agentul de stingere a incendiului cu gaz este unul dintre cele patru (Apă, spumă, chimice uscate și gaze) agenți tradiționali de stingere a incendiilor, printre ele, HFC-227EA Heptafluoropropan are proprietăți excelente curățenie și eficiență ridicată, acum a devenit un agent de stingere a incendiilor cu gaz curat utilizat pe scară largă.

Pentru că halonul 1211 și 1301 were phased out because it would destroy the atmospheric ozone layer, după aceea, S-a născut HFC-227ea, HFC-227ea a devenit produsul alternativ halon și popular.

În anii 1990, acest sistem HFC-227ea FM200 intră în China și China sisteme de stingere a incendiilor, deoarece produc acest produs și îl îmbunătățesc, cercetăm un sistem bazat pe locuințe de cabinet.

Cabinet de tip FM200 sistem de suprimare este mult mai ușor de operat și instalat decât cele complexe de conducte de sistem în alte țări, l-am numit ” Cabinet tip clean agent de stingere a incendiilor Sistem”, principala sa substanță chimică este HFC-227es, asa ca am sunat, de asemenea, ” Sistem FM200 tip cabinet”.

HFC-227ea este principalul produs chimic care este utilizat în întreaga lume pentru stingerea incendiilor și foarte popular, aproape peste 50% a sistemelor de stingere a incendiilor adoptă HFC-227ea ca agent principal, deci, evident,, sistemul de suprimare FM200 este cel mai popular sistem din lume, Sistemul NOVEC1230 încă nu se poate potrivi cu el.

Un sistem complet de heptafluoropropan este format din mai multe componente, există: supapă container, Cilindrul agentului, HFC-227EA Agent, Sifon, Dispozitiv de feedback al semnalului, Supapă electromagnetică, furtun de înaltă presiune, duze etc.

Când funcționează sistemul, va inunda total întreaga cameră prin pulverizarea agentului de suprimare a HFC-227ea, în 10 secunde se va suprima focul cu succes, și după descărcare, gazul de stingere va fi disipat automat și va fugi, și nu lăsați reziduuri.

După instalarea sistemului de stingere, este deja în stare de funcționare automată, atunci când se produce un incendiu în pericole, detector de căldură, detectorul de fum și alte elemente de detectare a temperaturii vor defecta focul, și transportați semnalul de alarmă de incendiu la panoul de control al incendiului de gaz, panoul de control va trimite ordinul de activare pentru a porni dispozitivul fm200 de stingere a incendiilor, și după 30 secunde întârziere de timp, dispozitivul de suprimare FM200 va începe să suprime focul; în același timp,, panoul de control va trimite semnal stroboscopului&corn, semnal de alarmă, semnalizarea de avertizare privind eliberarea gazelor, pentru a le reaminti oamenilor de la fața locului să plece repede.

SPECIFICAȚIE ȘI PARAMETRU

Mai jos sunt câțiva parametri de bază ai acestui produs:

  • Nume produs: Non-conducte Clean Agent Cabinet FM200 Sistem de stingere a incendiilor
  • Model: Stilul GQQ.
  • Mod de instalare: tip fix.
  • Presiunea de stocare: sub 20°C, este 2.5 Mpa.
  • Presiunea maximă de lucru: 4.2 Mpa.
  • Agent: HFC-227EA.
  • Densitatea de umplere a agentului: ≤1120 kilograme pe metru cub.
  • Dimensiunea cilindrului de depozitare a agentului: 40, 70L, 90L, 100L, 120L, 150L, 180L, în litri.
  • Calitatea agentului stâng după descărcarea de gestiune: 0 spre 3 Kilograme.
  • Temperatura ambiantă: 0 spre 50 °C.
  • Mod de activare: DC 24 Volt și 1.2 Un (Pornire electrică), ≤150N (Pornire pneumatică și Pornire manuală).
  • Suprimarea timp de întârziere: Mai puţin 30 Secunde.
  • Timp de descărcare: Mai puţin 10 Secunde.
  • Materialul cilindrului: Oțel carbon de înaltă calitate cu lustruire și acoperire roșie.
  • Modul de stingere a incendiilor: Inundații totale.
  • Clasa de stingere a incendiilor: Foc solid, Foc lichid, Foc de gaz, Foc electric.
  • Standard executiv: GB16670-2006, NFPA, UL.

INSTALLATIN MANUAL

Pentru mai multe detalii despre acest produs va rugam sa cititi MANUALUL DE INSTALARE A CABINETULUI DE TIP FM200 Atent.

 

CARACTERISTICI

  • Not require any cylinder storage rooms to place this system.
  • Can install in a single protection room seperately.
  • Easy to install and operate.
  • HFC-227ea is a clean agent, not cause any pollution to the environment, Mai mult, not have any bad affect on human body.
  • It can completely work with gas fire alarm systems.

APLICAŢII

  • Computer Room.
  • Server Room.
  • Switchgear Room.
  • Control Room.
  • UPS Battery Room.
  • Energy Storage System Room.
  • Power Supply Room and Power Plant.
  • Substation.
  • Academy.
  • Water Treatment Plant.
  • Generator Room.
  • Libraries, Museums and Archives.
  • Data Center.
  • Bus Station, Train Station, Airport and Seaport.
  • Communication Base Station.
  • Bank Vault.
  • TV Broadcasting Center.
  • Research and development building.
  • Paint room.
  • Chemical warehouse.
  • Waste water treatment station.
  • Oil Depot etc.

INSTALLATIN

Please do installation as per below point:

  • The cabinet must be placed at the site marked in gas suppression drawings of protection area, and the cabinet is suggested to install near wall, it is also necessary to ensure that the cabinet is stable without shaking and lean.
  • The bottle group of extinguishing agent must be moved to the center of cabinet, its frond side must face the outward direction, and it also must be fixed on the cabinet by using hoops and hooks, be careful and not crush the cabinet.
  • The nozzle must be installed at the nozzle hole at the top of the cabinet, the discharging must be carried out at outward direction against the cabinet, the inner part must be fixed on the cabinet by using clamp nuts.
  • The joint of high-pressure hose with elbow must be installed on the outlet thread of container valve and be screwed down using wrench, the other side must be connected to the thread at the nozzle end.
  • After debugged, the pressure signal device must be installed at the relevant interface of high-pressure hose.
  • The gas pressure gauge must be installed at the interface container valve.
  • The electromagnetic actuator (valve) must be installed on the container valve of gas storage bottle; as for double bottle group, the electromagnetic actuator must be installed at the container valve of driving storage bottle and the pneumatic actuator must also must be installed at the container valve of driving storage bottle.
  • In the installation of double-bottle group start-up pipeline, the container valve of driving bottle and the pheumatic actuator of driven bottle must be connected. this part can not be installed in the event that the deviation in distance between two bottle groups. At this moment, it is necessary to adjust the location of two bottle groups slightly.
  • Lines of pressure signal device and electromagnetic actuator must be traversed through the reserved thread hole behind the cabinet and connected to the gas fire control panel or control center. pay attention to use the protection tube in order to avoid damaging to the lines.
  • Each part which has been installed and connected must be checked again and again. it is necessary to ensure the firm fixing, good connection and sealing of pipeline and correct line connection, therefore, the installation of the whole set of cabinet type HFC-227ea fire suppression equipment is completed.

 

SYSTEM DEBUGGING

Do this system debugging as per the following:

  • Start-up test of electromagnetic actuator, take down the electromagnetic actuator, plug out the safety pin and connect the 24VDC test power, test the operation of the electromagnet linkage switch blade. after the test, the switch blade and safety pin in the electromagnetic actuator must be reset.
    Attention: Debugging of the electromagnetic actuator must be independently conducted without the container valve.
  • Test of storage pressure: unscrew the nut behind the pressure gauge in the counter-clockwise manner until it shows, the indicator in green area means normal state. After the test, remember to tighten the nut, in order to ensure that the pressure gauge will not damaged or leaked because of long-term under high pressure.
  • Feedback signal simulation: two lead wires of the short circle pressure signal device simulate the discharging feedback signals.
  • Debugging of gas fire control panel: Conduct automatic, manual and emergency start-up/stop debugging, be subjected to requirements of the Specifications of Gas Extinguishing System Construction and Acceptance.
  • After the qualified debugging job is well done, the electromagnetic actuator must be installed on the container valve of extinguishing agent carefully. The pressure signal device must be installed on the relevant interface of high-pressure hose and connected to the signal feedback line.
  • After the completion of the acceptance by the fire department and training of the user organization, the start-up lines of the electromagnetic actuator must be connected. plug out the safety pin of the electromagnetic actuator, the equipment must be in formal operation.

Formular de solicitare ( vă vom primi înapoi cât mai curând posibil )

Nume:
*
E-mail:
*
Mesaj:

Verificare:
4 + 5 = ?

Poate vă place, de asemenea,

  • DE CE SĂ NE ALEGEȚI PE NOI

    Suntem un ISO 9001, ISO14001, Iso18001 producător certificat specializat în sistemul de stingere a incendiilor pentru un deceniu de ani, folosim materiale de cea mai bună calitate pentru a produce produsele și toate acestea au trecut strict de inspecția QC înainte de a părăsi fabrica, cele mai multe dintre produsele noastre au primit certificate și aprobări de CE, RHOS, IP67, GL, Limba chineză de test Raport de la Institutul China.

  • CONTACTATI-NE

    Jiangxi Aware Fire Technology Co, Ltd

    Adresă: Număr 112, Districtul Yushui, Orașul Xinyu, Provincia Jiangxi, Republica China.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com