Počítačový priestor Server Rack Aerosólový protipožiarny systém

Floor standing aerosol chemical based fire prevention system is ideal solution for any enclosure space with area of 30 do 2000 Kubických, napríklad, if a computer room or sever rack room is in a size of 10*8*4 Metrov, then several sets of this device would be able to install in the corner of the room as a fire suppression solution.

In case the space is below 30 Kubických, then another series of MINISOL aerosol will be the best solution; in case space is below 1 cubic meter, then we suggest the Lithium-ion Battery style Aerosol.

  • Popis
  • Funkcie a aplikácia
  • Ďalšie informácie
  • Ďalšie preventívne opatrenia

ZÁKLADNÉ INFORMÁCIE

K dispozícii je aerosólový protipožiarny systém, ktorý vyzerá ako klimatizácia, môže stáť na podlahe a nevyžaduje žiadnu inštaláciu.

Je to dokonca halónová alternatíva a alternatíva HFC-227ea v niektorých špeciálnych oblastiach, napríklad: Malá počítačová miestnosť, serverové regály, telekomunikačná miestnosť a iné.

Podlahový stánok aerosól je pokročilý produkt šetrný k životnému prostrediu s pokročilou technológiou, Je to najnovšia tretia generácia aerosólu S.

Aerosólová technológia pochádza z raketovej technológie ruskej armády, a potom nejaká ruská high-tech spoločnosť vyrába prvú generáciu aerosólového systému, my Jiangxi Aware Fire Technology Co., Ltd sú prvý dovoz aerosólovej technológie z Ruska, a vylepšili svoju technológiu, aby vytvorili našu china unique aerosól-Strontium Nitrate Based, ktorý je oveľa šetrnejší k životnému prostrediu a šetrnejší k ľuďom ako aerosól na báze dusičnanu draselného.

Typ státia podlahy je len elektrický nábeh, ale môže byť schopný mať signálnu spätnú väzbu, nižšie vysvetlíme jeho vlastnosti a údaje.

ŠPECIFIKÁCIE A PARAMETRE

V nasledujúcom texte uvádzame naše hlavné technické parametre:

  • Typ výrobku: Typ státia alebo prízemia podlahy.
  • Vzorka: AW-QRR5LW/S, AW-QRR7.5LW/S, AW-QRR8LW/S, AW-QRR10LW/S.
  • Štýl aktivácie: Elektrický štart.
  • Objem krytu: Z 35 m3 až 71 m3.
  • Čas vybíjania: menej ako 120 Sekúnd.
  • Veľkosť: Pozrite si NÁVOD NA INŠTALÁCIU.
  • Teplota okolia: od -20°C do +55°C.
  • Relatívna vlhkosť: ≤98%.
  • Skutočná účinnosť hasenia: 130-150 gram na meter kubický.
  • Povrchová teplota valcov: menej ako 100°C.
  • Farba valca: strieborná biela a/alebo červená.
  • Teplota výtoku: menej ako 180 °C (5mm vzdialenosť od výtoku.)
  • Štýl signálu spätnej väzby: Normálne otvorenie.
  • Hodnotený počiatočný prúd: 1 do 1.2 A.
  • Štartovacie napätie: Jednosmerný prúd: 3 do 24 volt; Striedavý prúd: 3 do 240 volt.
  • Životnosť: 7 do 10 Rokov.
  • Typ potlačenia požiaru: A, B, C, E.
  • Režim inštalácie: Držiak so skrutkami; a magnetické s 3M lepidlom.
  • Podporné vybavenie: Požiarne poplachové systémy.

Uplatňuje sa hlavne v tých uzavretých priestoroch, kde sa objem pohybuje od 30 do 2000 Kubických, napríklad: počítačové miestnosti, miestnosti na výrobu elektrickej energie a iný priestor.

FUNKCIE

An old technician in our workshop design out this style of aerosol device, which is similar like a external machine of air conditioner, His design was inspired by air conditioning, we all admire him.

Get back to the point, the features as follow:

  • It should be installed in enclosure space, not in open area.
  • It should use in those space range from 30 do 2000 Kubických, and over 2000m3 you would better use a FM200 fire protection system.
  • It is clean product, do not worry about that it will do any damage to your machinery and equipment.
  • It leaves no residue after spraying, do not require you to sweep the room.
  • It is with a special cooling technology, so when it releasing the aerosol outlet temperature is not very hot.
  • It is a non-piping system, and do not worry about the problem of leakage.
  • Life span over 7 do 10 Rokov, and during its service time, people do not need to do any maintenance on it.
  • Pass the fire test and inspection test from China official research institute, and get CE certificate for approval.
  • Do not require you to install it with any tools, just place it on the floor in the room.

APLIKÁCIE

  • High-rise Buildings.
  • Power Distribution Room.
  • Library Room.
  • Archives Room.
  • Reference Room.
  • Storage Room.
  • Telecommunication Room.
  • Computer Rooms.
  • Communication Stations.
  • Railway Stations.
  • Distribution Ark.
  • Data Processing.
  • Remote Control.
  • Train Locomotive.
  • High Mobile Equipment Machine Room.
  • Signal Station Room.
  • Data Base Room.

RESTRICTED APPLICATION

This device not be able to apply in the following fields:

  • Chemical Substance which can be oxidized rapidly without air.
  • Active Metal.
  • Spontaneous Combustion Substance.
  • Metal Hydroxide.
  • Strong Oxidant.

ATTENTION FOR PRODUCT INSTALLATION

  • The installation job should be done by a professional person or skilled technician.
  • The device better installed near the wall.
  • The device should not be installed near wind, vent, door, window and other opening outlet.
  • Do not install it in a place where easy to get rain and water.
  • Do not install it near source of fire flame.
  • Do not install in evacuation exit.
  • Do not install it in a place where easy to get shocked, impacted and corrosion.
  • Mechanical ventilation equipment should be set at a underground pipe gallery or place without windows.
  • The device's activation wire better use twisted pair wire, or use dual-core metal shielded wire and the wire size better is 1.5 mm2.

ATTENTION FOR USE

Please read our instruction manual carefully before installation.

  • The job of installation and system commissioning must be done by a skilled personnel.
  • After installation, do not move the device easily.
  • In case of fire, personnel at site should leave immediately, and before leave please close the doors and windows as possible as you can.
  • The life span of this device is 7 years normally, after the service life time, please consider to replace it with a new one.
  • After releasing, don't touch the cylinder, because it is too hot, after cool down please wear gloves to move it.
  • In case of any accident, please do not dismantle the device without permission from the manufacturer or authorized agent.
  • The standby power of fire alarm system is forbidden to charge continuously for 24 hours, and the standby power should be replaced every 4 Rokov.
  • The inspector should check the fire alarm system yearly and keep record, but do not need to check this device yearly.
  • Before put in use, the installer should make sure that the power is off, in case of any device activated by mistake.

PREPRAVA A SKLADOVANIE

  • Handle with care during its transportation.
  • Store the device at a ventilated and dry warehouse.

AFTER SALES SERVICE

  • Záručná doba: 1 do 2 years based on manufacturing date.
  • Any technician question and doubt please feel free to inquiry from us.
  • After sale we can teach you how do install and how to do system debugging.

Formulár na začatie zisťovania ( Ozveme sa vám čo najskôr )

Meno:
*
E-mail:
*
Správa:

Overenie:
2 + 6 = ?

Možno sa vám tiež páči

  • PREČO SI VYBRAŤ NÁS

    Sme ISO 9001, ISO14001, Certifikovaný výrobca ISO18001 sa špecializuje na protipožiarny systém po dobu desiatich rokov, na výrobu výrobkov používame špičkovú kvalitu materiálu a všetky z nich prešli striktnou kontrolou QC pred odchodom z továrne, väčšina našich produktov má certifikáty a approvlas CE, RHOS, IP67, GL, Správa o čínskom jazyku testov z Čínskeho inštitútu.

  • KONTAKTUJTE NÁS

    Jiangxi Aware Fire Technology Co., Ltd

    Adresa: Číslo 112, Okres Yushui, Mesto Xinyu, Provincia Ťiang-si, Čínska republika.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com