Cabinet Type FM200 system is a non-piping system for total flooding the hazard, it use the most clean agent HFC-227ea as suppression chemicals, widely installed in power rooms, data rooms, computer rooms etc.

with cabinet over there, then you can install it in the room space, no need for other additional cylinder rooms.

It will not cause any harm to the human body and the environment, it is halon alternative.

 

  • Popis
  • Funkcie a aplikácia
  • Ďalšie informácie
  • Ďalšie preventívne opatrenia

VŠEOBECNÝ OPIS

Hasiaci prostriedok je jedným zo štyroch (Voda, pena, suchá chemikália a plyn) tradičné hasiace činidlá, medzi nimi, HFC-227EA Heptafluoropropane má vynikajúcu čistotu a vysokú účinnosť, teraz sa stal široko používaným čistým plynovým hasiacim činidlom.

Pretože halón 1211 a 1301 boli postupne vyradené, pretože by to zničilo atmosférickú ozónovú vrstvu, potom, Narodil sa HFC-227ea, HFC-227ea sa stáva halónovým alternatívnym produktom a populárnym.

V 90. rokoch, tento systém HFC-227ea FM200 prichádza do Číny a Číny protipožiarne systémy, pretože vyrábajú tento produkt a vylepšujú ho, skúmame systém založený na bývaní kabinetu.

Supresívny systém fm200 je oveľa jednoduchšie na obsluhu a inštaláciu ako tento komplexný potrubný systém v iných krajinách, Pomenovali sme to ” Skriňový typ Čistiace činidlo Protipožiarny systém”, Jeho hlavnou chemickou látkou je HFC-227es., Tak sme tiež volali ” Skriňa typu FM200 Systém”.

HFC-227ea je hlavnou chemickou látkou, ktorá sa používa po celom svete na potlačenie požiaru a je veľmi populárna., Takmer po všetkom 50% protipožiarne systémy prijímajú HFC-227ea ako hlavného činiteľa, takže je zrejmé, Supresívny systém FM200 je najpopulárnejším systémom na svete, Systém NOVEC1230 sa s ním stále nedokáže vyrovnať.

Kompletný heptafluoropropánový systém sa skladá z mnohých zložiek, existujú: kontajnerový ventil, Valec agenta, HFC-227EA Agent, Sifón, Zariadenie na spätnú väzbu signálu, Elektromagnetický ventil, vysokotlaková hadica, dýzy atď..

Keď systém funguje, úplne zaplaví celú miestnosť rozprašovaním supresívneho činidla HFC-227ea, Do 10 Sekundy úspešne potlačí oheň, a po vybití, hasiaci plyn sa automaticky rozptýli a utečie, a nezanechávať žiadne zvyšky.

Po nainštalovaní hasiaceho systému, Je už v automatickom pracovnom stave, Keď dôjde k požiaru v nebezpečenstve, detektor tepla, detektor dymu a iné prvky na snímanie teploty spália požiar, a prepraviť požiarny poplachový signál na ovládací panel plynového požiaru, ovládací panel vyšle príkaz na aktiváciu na spustenie protipožiarneho zariadenia FM200, a po 30 sekundové časové oneskorenie, supresívne zariadenie FM200 začne potláčať oheň; zároveň, ovládací panel vyšle signál do stroboskopu&roh, budík, Výstražné značenie uvoľňovania plynu, pripomenúť ľuďom na mieste činu, aby rýchlo odišli.

ŠPECIFIKÁCIA A PARAMETER

Nižšie sú uvedené niektoré základné parametre tohto produktu:

  • Názov produktu: Systém na potlačenie požiaru FM200, ktorý nie je potrubný clean agent Cabinet FM200
  • Model: Štýl GQQ.
  • Režim inštalácie: pevný typ.
  • Skladovací tlak: menej ako 20°C, je to 2.5 Mpa.
  • Maximálny pracovný tlak: 4.2 Mpa.
  • Agent: HFC-227EA.
  • Hustota výplne agenta: ≤1120 kilogramov na meter kubický.
  • Veľkosť akumulátorového skladovacieho valca: 40, 70L, 90L, 100L, 120L, 150L, 180L, v litroch.
  • Kvalita ľavého agenta po prepustení: 0 do 3 Kilogramov.
  • Teplota okolia: 0 do 50 °C.
  • Aktivačný režim: DC 24 Volt a 1.2 A (Elektrický štart), ≤150N (Pneumatický štart Manuálny štart).
  • Čas oneskorenia potlačenia: menej ako 30 Sekúnd.
  • Čas vybíjania: menej ako 10 Sekúnd.
  • Materiál valca: Vysoko kvalitná uhlíková oceľ s leštením a červeným povlakom.
  • Režim potlačenia požiaru: Totálne záplavy.
  • Trieda protipožiarnej ochrany: Pevný oheň, Tekutý oheň, Plynový oheň, Elektrický oheň.
  • Výkonný štandard: GB16670-2006, NFPA, UL.

INSTALLATIN MANUÁL

Viac informácií o tomto produkte nájdete v čítaní INŠTALAČNÝ MANUÁL SKRINE TYPU FM200 starostlivo.

 

FUNKCIE

  • Not require any cylinder storage rooms to place this system.
  • Can install in a single protection room seperately.
  • Easy to install and operate.
  • HFC-227ea is a clean agent, not cause any pollution to the environment, navyše, not have any bad affect on human body.
  • It can completely work with gas fire alarm systems.

APLIKÁCIE

  • Computer Room.
  • Server Room.
  • Switchgear Room.
  • Control Room.
  • UPS Battery Room.
  • Energy Storage System Room.
  • Power Supply Room and Power Plant.
  • Substation.
  • Academy.
  • Water Treatment Plant.
  • Generator Room.
  • Libraries, Museums and Archives.
  • Data Center.
  • Bus Station, Train Station, Airport and Seaport.
  • Communication Base Station.
  • Bank Vault.
  • TV Broadcasting Center.
  • Research and development building.
  • Paint room.
  • Chemical warehouse.
  • Waste water treatment station.
  • Oil Depot etc.

INSTALLATIN

Please do installation as per below point:

  • The cabinet must be placed at the site marked in gas suppression drawings of protection area, and the cabinet is suggested to install near wall, it is also necessary to ensure that the cabinet is stable without shaking and lean.
  • The bottle group of extinguishing agent must be moved to the center of cabinet, its frond side must face the outward direction, and it also must be fixed on the cabinet by using hoops and hooks, be careful and not crush the cabinet.
  • The nozzle must be installed at the nozzle hole at the top of the cabinet, the discharging must be carried out at outward direction against the cabinet, the inner part must be fixed on the cabinet by using clamp nuts.
  • The joint of high-pressure hose with elbow must be installed on the outlet thread of container valve and be screwed down using wrench, the other side must be connected to the thread at the nozzle end.
  • After debugged, the pressure signal device must be installed at the relevant interface of high-pressure hose.
  • The gas pressure gauge must be installed at the interface container valve.
  • The electromagnetic actuator (valve) must be installed on the container valve of gas storage bottle; as for double bottle group, the electromagnetic actuator must be installed at the container valve of driving storage bottle and the pneumatic actuator must also must be installed at the container valve of driving storage bottle.
  • In the installation of double-bottle group start-up pipeline, the container valve of driving bottle and the pheumatic actuator of driven bottle must be connected. this part can not be installed in the event that the deviation in distance between two bottle groups. At this moment, it is necessary to adjust the location of two bottle groups slightly.
  • Lines of pressure signal device and electromagnetic actuator must be traversed through the reserved thread hole behind the cabinet and connected to the gas fire control panel or control center. pay attention to use the protection tube in order to avoid damaging to the lines.
  • Each part which has been installed and connected must be checked again and again. it is necessary to ensure the firm fixing, good connection and sealing of pipeline and correct line connection, therefore, the installation of the whole set of cabinet type HFC-227ea fire suppression equipment is completed.

 

SYSTEM DEBUGGING

Do this system debugging as per the following:

  • Start-up test of electromagnetic actuator, take down the electromagnetic actuator, plug out the safety pin and connect the 24VDC test power, test the operation of the electromagnet linkage switch blade. after the test, the switch blade and safety pin in the electromagnetic actuator must be reset.
    Pozornosť: Debugging of the electromagnetic actuator must be independently conducted without the container valve.
  • Test of storage pressure: unscrew the nut behind the pressure gauge in the counter-clockwise manner until it shows, the indicator in green area means normal state. After the test, remember to tighten the nut, in order to ensure that the pressure gauge will not damaged or leaked because of long-term under high pressure.
  • Feedback signal simulation: two lead wires of the short circle pressure signal device simulate the discharging feedback signals.
  • Debugging of gas fire control panel: Conduct automatic, manual and emergency start-up/stop debugging, be subjected to requirements of the Specifications of Gas Extinguishing System Construction and Acceptance.
  • After the qualified debugging job is well done, the electromagnetic actuator must be installed on the container valve of extinguishing agent carefully. The pressure signal device must be installed on the relevant interface of high-pressure hose and connected to the signal feedback line.
  • After the completion of the acceptance by the fire department and training of the user organization, the start-up lines of the electromagnetic actuator must be connected. plug out the safety pin of the electromagnetic actuator, the equipment must be in formal operation.

Formulár na začatie zisťovania ( Ozveme sa vám čo najskôr )

Meno:
*
E-mail:
*
Správa:

Overenie:
2 + 7 = ?

Možno sa vám tiež páči

  • PREČO SI VYBRAŤ NÁS

    Sme ISO 9001, ISO14001, Certifikovaný výrobca ISO18001 sa špecializuje na protipožiarny systém po dobu desiatich rokov, na výrobu výrobkov používame špičkovú kvalitu materiálu a všetky z nich prešli striktnou kontrolou QC pred odchodom z továrne, väčšina našich produktov má certifikáty a approvlas CE, RHOS, IP67, GL, Správa o čínskom jazyku testov z Čínskeho inštitútu.

  • KONTAKTUJTE NÁS

    Jiangxi Aware Fire Technology Co., Ltd

    Adresa: Číslo 112, Okres Yushui, Mesto Xinyu, Provincia Ťiang-si, Čínska republika.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail: sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com