China Top Ten Enterprises in Fire Protection and Security Industry
EnglishবাংলাБългарскиΕλληνικάItalianoLatīnaLatviešu valodaLietuvių kalbaPortuguêsRomânăSlovenčinaEspañolBasa SundaKiswahiliWikang Filipino
» Superfine Dry Powder Fire Extinguishing Systems ABC style » Unpressurized Super-fine ABC dry powder extinguishing safety device

Unpressurized Super-fine ABC dry powder extinguishing safety device

Unpressurized Super-fine ABC dry powder fire extinguishing device is non-dangerous goods, which we use to suppress many kinds of fires, in international shipping, we always call it "Safety device" , because it is a product for peoples safety.

  • Description
  • Features and Applications
  • Extra Information
  • Other Precautions

INTRODUCTION

The unpressurized supfer-fine ABC dry powder extinguishing safety device uses propellant as the driving medium to make the device start to extinguish fire, it is made up of carbon dioxide cylinder, super-fine ABC dry chemical fire extinguishing agent, propellant, aluminum film, gas generator, installation bracket, closure head, gasket, activation wire etc.

It use propellant as driving gas to make the ABC dry powder running out of the storage cylinder and suppress fire, it not only total flooding, but also direct-to-source local application; not only for enclosure space, but also for open area fire protection.

Below are its basic Parameters and Data Sheet:

  • Style: Non-pressurized type.
  • Extinguishing agent: Super-fine ABC dry chemical powder.
  • Models: AW-FFX-ACT2.5, AW-FFX-ACT 3, AW-FFX-ACT5, AW-FFX-ACT8, AW-FFX-ACT10. (for detailed models please refer to www.awarefire.com).
  • Chemical quality: 2.5 kilograms, 3 kilograms, 5 kilograms, 8 kilograms, 10 kilograms.
  • Activation volt: DC 3 to 24 V (0.3 A to 0.5 A).
  • Activation temperature: 68℃ adjustable.
  • Thermal Temperature: 175℃ (if require).
  • Total flooding volume: from 20 to 100 cubic meters, for details refer to our Installation Manual.
  • Effective extinguishing time: less than 10 seconds.
  • Working temperature: -40 to +50℃.
  • Relative humidity: ≤95%.
  • Extinguishing Reaction force and time: 1.6KN/12ms, 1.8kn/13ms, 2.2kn/15ms, 2.6kn/18ms.
  • Safe current: ≥150mA.
  • Minimum startup current: 220 to 360 mA.
  • Resistance: 2.4 to 3.4 ohm.
  • Installation height: 3.5 to 8.5 meters.
  • Life span: 5 to 10 years.
  • Fire Suppression Type: Class A, Class B, Class C, Class E.
  • Executive Standard: GA602-2013.

 

FEATURES AND ADVANTAGES

  • Non-pressurized, Non-blasting, with solid gas driving technology.
  • Intelligent, Automatically to startup, Reduce the probability of wrong operation.
  • Non-conductive, non-corrosive, non-toxic, ODP value is zero, GWP value is zero and ALT value is also zero.
  • Clean product, it is easy to clean up after discharging.
  • Instanoues, instant fire extinguishing and early restaining.
  • Widely apply in many industries, and specially can be used in frigid zone.
  • Easy to install and operate, small size and space saving.
  • Cost effective and Economical, without pipeline network and pressurized cylinders.

APPLICATION

  • Switch Rooms.
  • Transformer rooms.
  • Cable Well.
  • Urban Underground Pipe gallery.
  • Car Garage.
  • Archives, Library, Museums.
  • Workplace.
  • warehouse.
  • Insurance rooms.
  • Telecommunication Base station.
  • Substation.
  • Gas Station.
  • Computer Rooms.
  • Modular Data Center Rooms.
  • IT security container.
  • Mobile server room.
  • Server racks.
  • IT security rack.
  • Ring main units.
  • Emergency Power and UPS.

THE DIFFERENCE

Difference between pressurized type and non-pressurized type ABC dry chemical:

  • Pressurized type have pressure to work, and non-pressurized type without pressure.
  • Pressurized one cause a little noise voice when it is discharging, but non-pressurized type have little noise.
  • The cost for produce non-pressurized type is a little higher than that of pressurized type.
  • The working principle of both of them is different, please refer to the user manual.
  • Pressurized one normally for enclosure space, but non-pressurized one for local application.

ABOUT TRANSPORTATION

  • Take precautions against collisions when transporting.
  • Handle with care.
  • Protect from sun and rain during transportation.

PRECAUTIONS

  • Do not disassemble this device without permission from factory.
  • Do not swallow the white inside dry powder fire extinguishing agent.
  • Do not let the children play with it.
  • Only technicians or specially trained professionals can install it.
  • Do the installation and system debugging job as per INSTALLATION MANUAL.

Enquiry Form ( we will get back you as soon as possible )

Name:
*
Email:
*
Message:

Verification:
2 + 4 = ?

Maybe you like also

  • WHY CHOOSE US

    We are a ISO 9001, ISO14001, ISO18001 certificated manufacturer specialize in fire suppression system for a decade of years, we use top quality of material to produce the products and all of them have pass strictly QC inspection before leaving factory, most of our products have got certificates and approvlas of CE, RHOS, IP67, GL, Chinese Language of Test Report from China Institute.

  • CONTACT US

    Jiangxi Aware Fire Technology Co.,Ltd

    Address: Number 112, Yushui District, Xinyu City, Jiangxi Province, Republic of China.

    Tel: 0086-0790-6000119
    Fax: 0086-0790-6001119
    E-mail:  sales@chinafiresuppresion.com
    Https://www.awarefire.com
    Https://aerosolfire.com
    Https://www.aerosolfireextinguisher.com
    Https://www.chinafiresuppression.com